- 35 -
5.3 Printer Initialization
Printer initialization is used to clear DRAM and restore printer settings to defaults. The only one exception is
ribbon sensitivity, which will note be restored to default.
Printer initialization is activated by the following procedures.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED
turns red and 5 blinks.
The LED will be changed as following:
red (5 blinks)
red (5 blinks)
red (5 blinks)
red (5 blinks)
green (5 blinks)
green (solid)
Printer configuration will be restored to defaults as below after initialization.
Parameter
Default setting
Speed
101.6 mm/sec (4 ips) (203DPI)
76 mm/sec (3 ips) (300DPI)
Density
8
Label Width
4” (101.5 mm)
Label Height
4” (101.5 mm)
Sensor Type
Gap sensor
Gap Setting
0.12” (3.0 mm)
Print Direction
0
Reference Point
0,0 (upper left corner)
Summary of Contents for TX200 Series
Page 1: ...USER S MANUAL TX200 TX300 TX600 Series THERMAL TRANSFER DIRECT THERMAL BAR CODE PRINTER ...
Page 5: ... iv HAZARDOUS MOVING PARTS KEEP FINGER AND OTHER BODY PARTS AWAY ...
Page 8: ... vii ...
Page 9: ......
Page 27: ... 18 Loading path for media ...
Page 42: ... 33 Numbers of download files Total available memory space Print head check pattern ...
Page 72: ......