3
INSTRUCTION MANUAL
SUBMERSIBLE PUMP
:
TPB1102
,
TPB5502
Original text translation
BEFORE YOU START USING THE PUMP READ
THOROUGHLY
THIS
MANUAL.
Keep this document for future reference.
Damages resulted from failure to follow the instructions
contained herein are not covered by the warranty.
triggered).
ź
The pump can work only in a vertical position.
ź
The pump cannot be used without water, as it may result in a serious
damage to the pump.
ź
Any cleaning can only be done with a jet of water. To clean its rotor it
is possible to remove its lower protective basket (turning on the
pomp in this state is prohibited). Any other disassembly results in a
SAFETY AND OPERATING CONTITIONS:
loss of warranty.
CAUTION. To limit the risk of fire, electric shock and
ź
The pumping delivery depends on the head. The pump cannot
injury while using power tools, follow all
deliver water to levels exceeding the maximum head provided in its
operating safety instructions. Any interruption of
specifications.
water delivery when the electric motor is on can
result in damage to the pump.
ź
When the pump has been assembled in a fixed system, its condition
should be checked every 3 months.
ź
After you unpack the device and before using it, check if all
ź
The pump cannot be used to carry liquid human waste!
components are present.
ź
Using the pump to carry wastewater (liquid human waste) will
ź
The tool should be used only for its intended purpose.
result in a rejection to repair the device (both under warranty and at
ź
The pump can be used only to handle water. Using it for carrying
extra charge).
other liquids is prohibited. The maximum water temperature cannot
ź
If any incorrect operation symptoms are detected, stop the machine
0
35
C.
immediately and disconnect it from its power source.
ź
To avoid electric shock prevent any contact with elements
conducting electric current or grounded (pipes, heaters, etc.).
ź
Keep away children and unauthorized persons from the operation
site.
ź
Do not damage the power cord. Do not carry the tool by its power
cord (power supply cable) and do not disconnect it from the power
source by pulling the cord. Keep the power cord away from the
sources of heat and oil and sharp edges. In case of damage, replace it
with a new one.
ź
Do not touch any rotating components, even if they rotate by inertia
only.
ź
Disconnect the tool from the power source if it is not in use or is being
serviced.
ź
Check its technical condition on a regular basis.
ź
Any cracks, loose components and other damages should be
rectified in an authorized service center. Only original parts should
be used to repair the device. Using a damaged power tool is
prohibited.
ź
To clean use a soft, slightly wet cloth and soap. Do not use petrol,
solvents or any other agents that may damage the device.
ź
The pump cannot be used in swimming pools or any other bathing
places when people are in the water. In such cases the pump must be
disconnected from the power source and removed from water.
ź
It is prohibited to hang the pump on its power cord or suction hose.
The pump can be suspended by the handle located in its upper part.
ź
The supply voltage must correspond to the value provided on the
device nameplate. The power grid the pump is supposed to be
connected to should be equipped with PE terminal and a circuit
protection of min. 6A. If people can be present in the vicinity of its
operation, the circuit should be equipped with a differential current
trip RC
D
with a rated current of min. 6A and differential current of
max. 30 mA.
ź
Water level must be approx.
11
cm above the lower pump edge.
When water drops below this level, the motor stops (float switch is
CONSTRUCTION AND APPLICATIONS:
The set includes a pump (
10
) driven by a single-phase asynchronous
motor, protective basket (
9
) float switch (
5
), suspension handle (
3
),
water connection (
6
) and power supply cable (power cord) (
2
) with a
plug (
1
) (see Fig.
A
).
The submersible pump is for domestic use, designed to carry dirty
water from reservoirs in interrupted operation mode. It is perfectly
suitable for use in cellars. When installed in a sump, it protects against
flooding. In addition to this, the devices can be used in all places where
it is necessary to transfer water e.g.: in households, farms, gardening
and many other sectors. The pump is not suitable to carry salt water
and flammable, caustic, explosive or other dangerous liquids.
Pumps are fitted with a thermal trip to provide protection against
overheating. The transferred liquid should be of room temperature
(max 35 °C), hardness pH 4-10, and solids content up to 2%.
Please pay attention to fix the pump in a stable way, especially when
operated in the automatic mode. Place the device to protect the pump
inlet against clogging (even partial); it is indicated to put it e.g. on a
brick. Do not carry the device holding by the power cord or the float
switch cable. Use the rope attached to the handle on the pump.
n
COMPONENTS
(see Fig.
A
)
:
1.
Plug
2.
Power cord (power supply cable)
3.
Suspension handle
4.
Float switch bracket
5.
Float switch (on/off)
6.
Water connection
7.
Connection thread (water connection)
8.
Water inlet
9.
Protective basket
10.
Pump
11.
Screws fixing the protective basket
Summary of Contents for TPB1102
Page 2: ...1 A 1 3 4 6 7 8 B 5 10 2 600 x 600mm 110 mm 360 mm ON OFF 600 mm 9 5 11...
Page 3: ...C 2 5 4 D...
Page 17: ...16 1 230 n 5 360 B ON OFF 110 360 1 Ph2 11 9 n 2 360 mm 5 4 D 3 110 1 1 1 2 3 4 5 2 3 4 5...
Page 27: ...26 5 1 230 60x60x60 5 B 2 360 B ON OFF 110 110 360 C 3 360 5 4 D 70 1 230 50 10 n n...
Page 28: ...27 1 Ph2 11 9 2 3 5 1 2 3 4 I i 34 03 228 I...
Page 39: ...TPB1102 TPB5502 38 n 6 30mA 11 3 35 C 6 10 9 5 3 6 2 1 max35 C 4 10pH 2 1 2 3 4...
Page 41: ...40 4 D 110 1 230 V 50 Hz 10A 1 Ph2 1 11 9 230V 2 n 5 360 3 B ON OFF 110 360 n 360 5 1...
Page 50: ...49...
Page 51: ...50...
Page 52: ...www profix com pl...