© Trynex International 2007 L1102
5 — 27
Center High Mount Stop Lamp (CHMSL)
Vee Pro 6000 and Vee Pro 8000 Models Only
•
With spreader mounted on vehicle, plug vehicle (CHMSL) harness into spreader stop lamp harness.
•
Using supplied harness clamps and screws, route harness along side wall lower corner or so that harness will be out of the way when
spreader is not in use.
•
Locate vehicle ground wire and stop lamp power wire at rear of vehicle. Use supplied wire taps to connect harness to vehicle electrical
system. Once wire taps are installed check to make sure stop lamp works when brake pedal is pressed. Properly complete installation
by tying up any loose wires with ty-wraps, also add electrical tape over both connections to insure a solid electrical connection. Some
newer trucks have auxiliary stop lamp power leads already at the rear for these types of applications.
Black Ground (–)
White Positive (+)
Splice into vehicle harness stop
lamp/CHMSL circuit.
Route along bed.
CHMSL Spreader Harness
(installed on Spreader from factory)
Key
Part
No. Description
Qty.
D 6158
#10 Lock Nut
2
D 6514
CHMSL Spreader Harness
1
D 6529
#10 Black Oxide Screw
2
Key
Part
No. Description
Qty.
D 6234
Butt Connectors
2
D
6513
CHMSL
Vehicle
Harness 1
D 6523
Scotch Locks
2
D 6560
Hex Head Screw
4
D 6561
Cable Mounts
4
CHMSL Vehicle Harness
Summary of Contents for SnowEx Vee Pro 3000
Page 8: ...L1102 Trynex International 2007 5 8 Vee Pro 3000 Side and Bottom View...
Page 9: ...Trynex International 2007 L1102 5 9 Vee Pro 6000 Side and Bottom View...
Page 10: ...L1102 Trynex International 2007 5 10 Vee Pro 8000 Side and Bottom View...
Page 12: ...L1102 Trynex International 2007 5 12 Vee Pro 3000 Parts Breakdown...
Page 14: ...L1102 Trynex International 2007 5 14 Vee Pro 6000 Parts Breakdown...
Page 16: ...L1102 Trynex International 2007 5 16 Vee Pro 8000 Parts Breakdown...
Page 21: ...Trynex International 2007 L1102 5 21 Electrical System Complete Assembly View...