4
z
Din rail or panel mounts support.
1-2 . Specification.
z
CPU:32 bit 170MHZ with MMU.
z
SDRAM:32MB.
z
FLASH:8MB.
z
Power Input Voltage: DC +10V to +30V.
z
LAN: Auto-MDIX, 10/100 Mbps Auto-detecting.
z
RS-232: RI,TX, RX, RTS, CTS, DTR, DSR, DCD, GND.
z
RS-422: TX+, TX-, RX+, RX-.
z
RS-485: Data +, Data –.
z
Data Rate: 75~921Kbps.
z
Parity: none, even, odd.
z
Data Bits: 5, 6, 7 or 8.
z
Stop Bits: 1, 1.5 or 2.
z
Configuration through Windows Admin Utility / Web Console / Telnet Console.
z
Supports Real COM mode using RFC 2217 protocol.
z
Protocol: ICMP, TCP/IP, UDP, DHCP, Boot, Telnet, DNS, SNMP, HTTP, SMTP, SNTP.
z
External P1/P2/P3 Port, each port can be connecting item below.
TRP-C08S
:USB to 1 RS232 and 1 RS422/485 Isolated Converter.
TRP-C08H
:USB to 2 RS232 and 2 RS422/485 Isolated Converter.
TRP-C08U
:USB to 4 RS232 Isolated Converter.
TRP-C08X
:USB to 4 RS232/422/485 Converter.
TRP-C29U
:USB to 8 Digital Input and 8 Digital Output Remote I/O.
z
Power supply: Screw terminal, or standard external DC adapter.
z
External P1, P2, P3 connector: USB A Type, support power consumption: 500mA/5V.
z
Serial interface: +/-15 KV ESD.
z
RS422/485 interface: Surge, over current, over voltage protection.
z
Power consumption: 12V/450 mA (without external device).
z
Operating Temperature: 0 to 65 °C.
z
Humidity: 0~90% Non-Condensing.
z
Dimensions: 145(L)*118(W)*26(H) /mm.
z
Weight: 728g (W/Packing).
Summary of Contents for TRP-C34H
Page 27: ...27 Step5 The Port Mapping will show below Step7 Right Click select Apply Change ...
Page 29: ...29 Step8 RUN Demo exe and select setting Step9 Select Action then clicks Connect ...
Page 33: ...33 5 3 Paired Mode Example ...
Page 35: ...35 b Port 2 Setting c Port 3 Setting ...
Page 37: ...37 a Port 1 Setting b Port 2 Setting ...
Page 38: ...38 c Port 3 Settings c Port 4 Setting ...
Page 40: ...40 ...
Page 41: ...41 6 TRP C34H Application Diagram ...
Page 42: ...42 ...