IP Grade
IP20
Power Requirements
3
CAZ-EL-4-1/2N2
13978
4
1
/
2
”
Class II
60 Hz
Tile and masonry saw
16 AWG x 2C with insulating temperature of 221 °F
50 minutes work per 20 minutes rest.
Maximum 6 hours daily.
11 A
1.7 Hp
Code
Description
Disc
Voltage
Frequency
Current
Power
11000 RPM
Speed
Duty cycle
Conductors
Insulating
Power cord grips used in this product: Y
Build quality: Double Insulating.
Thermal insulation on motor winding: Class E
120 V
ENGLISH
Technical Data
To prevent power discharge or serious accident if the power cable gets damaged
make it replaced by the manufacturer or in a Authorized Service Center.
Power insulation in this tool is affected by liquid spills or splashing while operating.
Do not expose to rain, liquids and / or humidity.
Before gaining access to terminals, all power circuits should be disconnected.
WARNING
WARNING
Tools with double insulation and reinforced insulation eliminate the need of a grounded
power cord with three prongs or a grounded power connection.
When using an extension cable, verify the gauge is enough for the power that your product
needs. A lower gauge cable will cause voltage drop in the line, resulting in power loss and overheating. The
following table shows the right size to use depending on cable’s length and the ampere capability shown in
the tool’s nameplate. When in doubt use the next higher gauge.
WARNING
WARNING
WARNING
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
18 AWG(*)
16 AWG
14 AWG
8 AWG
16 AWG
14 AWG
12 AWG
6 AWG
3 (one grounded)
from 5.9’ to 49.2’ | higher than 49.2’
Ampere
Capacity
Number of
Conductors
Extension gauge
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
When operating power tools outdoors, use a grounded
extension cable labeled “For Outdoors Use”. These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.