background image

3

DIMI-20A

101606

IP 20

0 - 2 600 RPM

Cordless impact screwdriver

Forward – reverse

103 lb-ft (140 Nm)

Code

Description

Tip holder

Voltage

Speed

Rotation

Maximum torque

Battery

 IP Grade

Input: 

Voltage: 

127 V

 

Frequency:  60 Hz

 

Power: 

40 W

Output:      12 V     - 21 V       1.5 A

Charger

Power Cord Grips used in this product: Type “Y”.

Tool build class is: Class III

Charger build class is: Reinforced Insulation

20 V

Ion-lithium 20 V      2 Ah    |    Charging time: 90 minutes’ approximately

0 - 3 250 strokes per minute

Strokes per minute

1/4”

ENGLISH

Power Requirements

Technical Data

Tools with double insulation are equipped with a polarized plug 

(one prong is wider than the other). This plug will only fit in the right way into a 

polarized outlet. If the plug cannot be introduced into the outlet, reverse the plug. If 

it still doesn’t fit, call a qualified electrician to install for you a polarized outlet. Do 

not alter the plug in any way. Double insulation eliminates the need of both a 

grounded third power cord with three prongs or a grounded power connection.

When using an extension cable, verify the gauge is enough for 

the power that your product needs. A lower gauge cable will cause voltage drop in the line, resulting in power loss and 

overheating. The following table shows the right size to use depending on cable’s length and the ampere capability shown in 

the tool’s nameplate. When in doubt use the next higher gauge.

WARNING

WARNING

WARNING

from 0 A and up to 10 A

from 10 A and up to 13 A

from 13 A and up to 15 A

from 15 A and up to 20 A

18 AWG(*)

16 AWG

14 AWG

8 AWG

16 AWG

14 AWG

12 AWG

6 AWG

3 (one grounded)

from 6 ft to 49 ft         |         higher than 49 ft

Ampere

Capacity

Number of

Conductors

Extension gauge

* It is safe to use only if the extensions have a built-in artifact for over current protection.

AWG = American Wire Gauge. Reference: NMX-J-195-ANCE

When operating power tools outdoors, use a                       grounded 

extension cable labeled “For Outdoors Use”. These extensions are especially designed 

for operating outdoors and reduce the risk of electric shock.

WARNING

WARNING

Avoid the risk of electric shock or severe injury. When the power cable gets damaged 

it should only be replaced by the manufacturer or at a                                 Authorized Service Center.

The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.

Do not expose to rain, liquids and/or dampness.

Before gaining access to the terminals all power sources should be disconnected.

Summary of Contents for 101606

Page 1: ...Manual Cordless impact screwdriver DIMI 20A Model Code DIMI 20A Applies for 101606 Tip holder 20 V 1 4 CAUTION Read this manual thoroughly before using the tool ENGLISH ESPA OL...

Page 2: ...Warranty Policy 3 3 4 5 6 6 9 9 9 10 11 12 DIMI 20A ENGLISH Contents CAUTION Keep this manual for future references The illustrations in this manual are for reference only They might be different fro...

Page 3: ...ds A lower gauge cable will cause voltage drop in the line resulting in power loss and overheating The following table shows the right size to use depending on cable s length and the ampere capability...

Page 4: ...om the moving parts Loose clothes or long hair may get caught in moving parts If you have dust extraction and recollection devices connected onto the tool inspect their connections and use them correc...

Page 5: ...f 1 hour and 30 minutes Avoid stopping constantly while screwing to avoid damage to the battery This tool is designed to operate with screws IT IS NOT A DRILL This is a light duty tool it should not b...

Page 6: ...ight will turn off Disconnect the charger from the power supply when charging is complete If the red light flashes the battery is defective replace it with a new one If the green light flashes the bat...

Page 7: ...ons for battery use Installing and removing the battery To screw in release the switch and press the direction of rotation button on the side where the marks point towards the drill bit To reverse dir...

Page 8: ...ng size Failure to use the correct fitting size will cause a reduction in tightening torque Bolt size Larger bolt diameters generally require more tightening torque Tightening torque also varies accor...

Page 9: ...n or clothing with soap and water Replace the battery immediately Insert the battery correctly into the charger Check that the plug is securely connected to the socket Allow the tool to cool for 5 min...

Page 10: ...Notes 10 ENGLISH...

Page 11: ...O DE SERVICIO ECLIPSE CALLE PRINCIPAL MZ 1 LT 1 COL SANTA FE C P 39010 CHILPANCINGO GRO TEL 747 478 5793 FERREPRECIOS S A DE C V LIBERTAD ORIENTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C P...

Page 12: ...regidora 22 Col Centro Alc Cuauht moc CDMX C P 06060 or at the establishment where you purchased it or at any Truper Service Center listed in the annex to the warranty policy and or in www truper com...

Page 13: ...Col Centro Alc Cuauht moc CDMX C P 06060 o en el establecimiento donde lo compr o en alg n Centro de Servicio Truper de los enlistados en el anexo de la p liza de garant a y o en www truper com Los g...

Page 14: ...0 88 CENTRO DE SERVICIO ECLIPSE CALLE PRINCIPAL MZ 1 LT 1 COL SANTA FE C P 39010 CHILPANCINGO GRO TEL 747 478 5793 FERREPRECIOS S A DE C V LIBERTAD ORIENTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL...

Page 15: ...Notas 10 ESPA OL...

Page 16: ...impie de inmediato con agua y jab n el l quido de la piel o ropa Reemplace la bater a de inmediato Inserte correctamente la bater a al cargador Revise que la clavija se encuentre bien conectada al tom...

Page 17: ...o del accesorio El no utilizar el tama o de accesorio correcto causar una reducci n en el par de ajuste Tama o del perno Los di metros mayores de pernos generalmente requieren un mayor par de ajuste E...

Page 18: ...Para atornillar suelte el interruptor y presione el bot n de direcci n de giro del lado en donde las marcas apuntan hacia el broquero Para invertir el sentido y desatornillar presi nelo del lado contr...

Page 19: ...argador de la corriente una vez concluida la carga Si la luz roja parpadea es se al de que la bater a est defectuosa reempl cela por una nueva Si la luz verde parpadea es se al de que la temperatura d...

Page 20: ...s terminales puede ocasionar quemaduras o incendio En condiciones severas puede derramarse l quido de la bater a evite el contacto Si hay contacto accidental lave la zona con agua Si hay contacto con...

Page 21: ...etire cualquier llave o herramienta de ajuste antes de arrancar la herramienta el ctrica Las llaves o herramientas que quedan en las partes rotativas de la herramienta pueden causar un da o personal N...

Page 22: ...El doble aislamiento elimina la necesidad de un cable de corriente de tres partes con conexi n a tierra o de un sistema de corriente el ctrica con conexi n a tierra Al usar un cable de extensi n aseg...

Page 23: ...ntros de Servicio Autorizados P liza de Garant a Guarde este instructivo para futuras referencias Los gr ficos de este instructivo son para referencia pueden variar del aspecto real de la herramienta...

Page 24: ...stornillador de impacto inal mbrico DIMI 20A Modelo C digo DIMI 20A Este instructivo es para 101606 Porta puntas 20 V ESPA OL ENGLISH ATENCI N Lea este Instructivo por completo antes de usar la herram...

Reviews: