3
Technical data
HILA-2000X
102111
2 000 PSI
Electric Pressure Washer
174 PSI
Power Requirements
In the event of faults or severe malfunction, the ground connection
delivers a trajectory with minimum resistance for power supply reducing the risk of
electric shock. This tool is built with a power cord with a connector and plug connected
to ground. The plug shall be connected into a power source installed and grounded
according to all the local codes.
When using an extension cord, verify the gauge is enough for the
power that your product needs. A lower gauge cord will cause voltage drop in the line, resulting in power loss and
overheating. The following table shows the right size to use depending on cord’s length and the ampere capability
shown in the tool’s nameplate. When in doubt use the next higher gauge.
WARNING
WARNING
ENGLISH
Code
Description
Maximum Pressure
Maximum Inlet Pressure
43.5 PSI
Minimum Inlet Pressure
Class I
60 Hz
14 AWG x 3C with 221 °F insulation temperature
50 min work per 20 min rest. Maximum 6 hours daily
16 A
16.5 ft
Frequency
26.2 ft
1.5 gpm
122 °F
127 V
Power cord grips: Type “Y”.
Washer Build Quality: Basic
Thermal insulation on motor winding: Class F
Maximum Water Flow
3.3 gpm
Input flow
Voltage
Current
2 100 W
Power
Power Supply Cable
High-Pressure hose
Duty Cycle
Conductors
Insulation
Maximum Inlet Temperature
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
18 AWG
16 AWG
14 AWG
8 AWG
16 AWG
14 AWG
12 AWG
6 AWG
3 (one grounded)
From 6 ft to 49 ft | Higher than 49 ft
Ampere
Capacity
Number of
Conductors
Extension Gauge
WARNING
When operating power tools outdoors, use a grounded
extension cable labeled “For Outdoors Use”. These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
Summary of Contents for 102111