12
Installing the OCB transfer device
1714400_ANGLE_MEAS
URING_SYSTEM_OCB
Correction input mask for OCB
The correction input mask for OCB is called up by the correction
buttons in production so that a bend that has just been performed
can be corrected whenever desired.
The two input fields for left and right corrective values (to enter the
measured angles) can be selected freely. The values can be
automatically entered with the OCB system or also manually with
the keyboard in the correction input box. The three measuring
position LEDs on the OCB broach are controlled by the selection of
the input fields for the measured angles.
Once an angle has been successfully transmitted by the radio link,
the next input field is selected right away in order to be able to
enter the angle there. In this way, the user can measure all
corrective angles and send them to the control without having to go
to the control after every angle measurement to manually switch-
over the input field at the control for the next angle input. If the red
LED lights up, then the measured angle is beyond the tolerance
range of ±10 degrees.
As an example, here an OCB application is run.
Entry of the left measured angle
Fig. 49853