Intended use
The Trumatic S 3002 FS liquid gas heater has been designed
for stationary installation in fixed awning structures.
The equipment must not be used in vehicles (campers)
or coaches.
The heater has a combustion air/exhaust circuit that is sealed
from the installation area.
Other applications are only permitted after prior consultation
with Truma.
Important operating notes
1. The combustion air intake (2) must be kept free of dirt and
slush.
2. Before switching on the heater in winter, clear all snow from
the cowl (4).
3. Inspect the exhaust duct and all connections at regular inter-
vals, and always in the event of blowback (misfire). It is essen-
tial for the exhaust duct to be installed so that it slopes upwards
over its whole length and is secured with several clamps. Never
place any object on the exhaust duct, since this could result in
damage. The exhaust duct connection to both the heater and
the cowl must be firm and well sealed. It is no longer per-
missible to operate heaters with incorrectly fitted or damaged
exhaust ducts!
4. Never allow the warm air outlet on the heater to be
obstructed in any way.
For instance never hang washing on
or in front of the heater to dry. Misusing your heater in this way
could cause serious damage from overheating. Do not place
flammable objects near the heater. Please follow these guide-
lines in the interest of your own safety.
Due to the design, the heating front case will
become hot during operation. The operator is
obliged to ensure that due care is taken to protect
third parties (small children in particular).
Trumatic S 3002 FS
Liquid gas heater for free-standing installation
in fixed awning structures
1 Liquid gas heater
Trumatic S 3002 FS
2 Combustion air intake
3 Exhaust duct with
insulating duct
4 Exhaust gas cowl
5 Trumavent fan TEB 2
6 Warm air pipes
7 Warm air outlets
8 Gas supply