11
Description
SDC12
SDC25
Capacity of Solar Panel
(recommended / max.)
50 - 165 Wp
50 - 350 Wp
Current Solar Panel
0 - 10 A
0 - 21.0 A
Voltage Solar Panel
(Voc):
max. 50 V
max. 50 V
Nominal Voltages of
Batteries Main I & Start II
12vDC
12vDC
Charging Current
0 - 12 A
0 - 25 A
Current Consumption
Stand-by (max.):
17mA
17mA
Ingress Protection Rating
IP30
IP30
Starter Battery
SDC12
SDC25
Charging Current
0 – 1.0 A
0 – 1.0 A
Overload Protection
Yes
Yes
Integrated Protection
against Short-circuit
Yes
Yes
Integrated Protection
against Overtemperature
Yes
Yes
Main Battery
SDC12
SDC25
Charging/Floating/Load
Current
0 – 12 A
0 – 25 A
Reset Voltage (30 sec)
12.7v
12.7v
Charging Voltage
Limitation (max.)
14.8v
14.8v
Overload Protection
(Current Limiting Device)
Yes
Yes
Integrated Protection
against Short-circuit
Yes
Yes
Integrated Protection
against Overtemperature
Yes
Yes
Integrated Cooling Fan
with Temp. Control
No
Yes
Unit Fuse (Type FKS)
20A
40A
Input for Main Battery
temperature sensor
Yes
Yes
Charger timer
3 stage
3 stage
Dimensions (mm)
147x74x40
147x74x40
Weight
338g
402g
Humidity (max)
95% RH, no condensation
Technical data
Summary of Contents for SDC12