Troubleshooting guide (Combi Diesel heating system)

Flashing code in analogue control panel – CP Classic
Flash sequence LED: 

 

– On / Off: 

0.5  seconds

Pause between flash sequence:  5  seconds

 Fault

 Cause

 Rectification

No LED illuminates
after switching on.

 

– No operating voltage

 

– Device fuse or vehicle fuse 

defective

 

– Check 12 V battery voltage, charge battery if necessary

 

– Check all electrical plug connections

 

– Check fuse of unit or vehicle, replace if necessary (see fuses)

The green LED illuminates when 
the unit is switched on, but the 
heating system does not operate

 

– The temperature setting on the 

control panel is lower than the 
room temperature

 

– Select higher room temperature at the control panel

Green LED flashes (with 5 Hz) 
after the heating system has been 
switched off

 

– After-running is active to reduce 

the temperature of the unit

 

– No fault, after-run switches itself off after max. 5 minutes 

Red LED flashes 6 x

 

– Lack of fuel due to insufficient 

fuel tank filling, tank has run 
empty and / or vehicle is on a 
slope

 

– Fill tank with fuel, then fill fuel line as described in "Initial start-up"

Red LED flashes (except 6 times)
or red LED permanently on

 

– Heater malfunction

 

– Please contact Truma Service

Yellow LED flashes 1 x

 

– Risk of low voltage

< 11.5 V

 

– Use the electrical power from the battery sparingly,

e.g. restrict lighting

 

– Charge battery

Yellow LED flashes 2 x

 

– Undervoltage < 10.2 V

 

– Check battery voltage, charge battery if necessary

 

– Short-term immediate action, switch off major consumers

or start up vehicle engine until the heating system starts running
(approx. 4 minutes)

 

– Battery capacity inadequate, if necessary exchange old battery

Summary of Contents for CP classic

Page 1: ...hren Operating instructions Page 13 Installation instructions Page 22 To be kept in the vehicle Mode d emploi Page 24 Instructions de montage Page 33 garder dans le v hicule Istruzioni per l uso Pagi...

Page 2: ...23 Assembly 24 Symbols used The unit must only be installed and repaired by an expert Note containing information and tips Please pay attention to the ESD regulations Electrostatic charge can destroy...

Page 3: ...ing or with drained water system Operating instructions e Heating and hot water mode heating with water temperature monitoring f Rotary switch Off g Yellow LED lit Boiler heat up phase yellow LED flas...

Page 4: ...he yellow LED o at the power selector switch indicates that the unit is operating with 230 V Heating with water temperature monitoring Move rotary switch on control panel to On position e Set the rota...

Page 5: ...elect the required operating level according to the tempera ture difference between the setting on the control panel and the current room temperature Once the room temperature selected on the control...

Page 6: ...ow LED o on the power selector switch illuminates and the red LED h or the yellow LED g on the control panel flashes Possible causes can be found in the troubleshooting guide If the flame goes out dur...

Page 7: ...the heating system does not operate The temperature setting on the control panel is lower than the room temperature Select higher room temperature at the control panel After switching on the heating...

Page 8: ...heck gas supply and open valves Gas cylinder empty Replacing a gas cylinder After operating for a longer pe riod of time the heating system switches to failure Gas pressure regulation system iced up U...

Page 9: ...th 5 Hz after the heating system has been switched off After running is active to reduce the temperature of the unit No fault after run switches itself off after max 5 minutes Red LED flashes 6 x Lack...

Page 10: ...s are connected Warm air outlets blocked Circulated air intake blocked Check whether the 4 warm air ducts are connected Check individual outlet apertures Remove blockage from circulated air intake Sum...

Page 11: ...istrative regulations of the respective country in which it is used National regulations and laws in Germany for example the End of life Vehicle Regulation must be observed Declaration of conformity T...

Page 12: ...tered see Truma Service Booklet or www truma com In order to avoid delays please have the unit model and factory number ready see type plate Veuillez vous adresser au centre de SAV Truma ou un de nos...

Reviews: