The unit automatically selects the required operating level 
according to the temperature difference between the setting 
on the control panel and the current room temperature. Once 
the room temperature selected on the control panel has been 
reached, the heating system switches off. The warm air fan 
will continue to run at a low speed as long as the blow-out 
temperature (on the unit) is higher than 40 °C. 

If the boiler has been filled, the water is automatically heat-
ed as well. The water temperature is then dependent on the 
heating output being given off, and the duration of heating 
required to reach the desired room temperature.

 

– Heating with 

drained

 water system

Move rotary switch on control panel to "On" position (d).

Set the rotary switch (a) to the desired thermostat setting 
(1 – 5). The green LED (b) for operation is lit and simultaneous-
ly indicates the position of the selected room temperature. The 
yellow LED (g) will only be lit if the temperature of the unit is 
below 5 °C!

Depending on the operating mode, the unit will automatically 
select the required operating level according to the tempera-
ture difference between the setting on the control panel and 
the current room temperature. Once the room temperature 
selected on the control panel has been reached, the heating 
system switches off. The warm air fan will continue to run at a 
low speed as long as the blow-out temperature (on the unit) is 
higher than 40 °C. 

Switching off

Switch off heating system at control panel using rotary switch 
(position f). The green LED (b) goes off.

Always drain water contents if there is a risk of frost!

Units with gas mode

If the unit is not going to be used for a long period of time, 
close the quick-acting valve in the gas supply line and turn 
off the gas cylinder.

Fault

Gas or diesel mode

In the event of a fault the red LED (h) or the yellow LED (g) on 
the control panel will flash.

Possible causes can be found in the troubleshooting guide.

A reset (fault reset) is carried out by switching off, waiting 
until all LED’s on the control panel have stopped flashing, and 
then switching the heating system on again. 

If the window to which a window switch is mounted is 
opened, the heater stops operating and the yellow LED (g) 

flashes 3 times. The heater continues operating when the win-
dow is closed. 

Summary of Contents for CP classic

Page 1: ...hren Operating instructions Page 13 Installation instructions Page 22 To be kept in the vehicle Mode d emploi Page 24 Instructions de montage Page 33 garder dans le v hicule Istruzioni per l uso Pagi...

Page 2: ...23 Assembly 24 Symbols used The unit must only be installed and repaired by an expert Note containing information and tips Please pay attention to the ESD regulations Electrostatic charge can destroy...

Page 3: ...ing or with drained water system Operating instructions e Heating and hot water mode heating with water temperature monitoring f Rotary switch Off g Yellow LED lit Boiler heat up phase yellow LED flas...

Page 4: ...he yellow LED o at the power selector switch indicates that the unit is operating with 230 V Heating with water temperature monitoring Move rotary switch on control panel to On position e Set the rota...

Page 5: ...elect the required operating level according to the tempera ture difference between the setting on the control panel and the current room temperature Once the room temperature selected on the control...

Page 6: ...ow LED o on the power selector switch illuminates and the red LED h or the yellow LED g on the control panel flashes Possible causes can be found in the troubleshooting guide If the flame goes out dur...

Page 7: ...the heating system does not operate The temperature setting on the control panel is lower than the room temperature Select higher room temperature at the control panel After switching on the heating...

Page 8: ...heck gas supply and open valves Gas cylinder empty Replacing a gas cylinder After operating for a longer pe riod of time the heating system switches to failure Gas pressure regulation system iced up U...

Page 9: ...th 5 Hz after the heating system has been switched off After running is active to reduce the temperature of the unit No fault after run switches itself off after max 5 minutes Red LED flashes 6 x Lack...

Page 10: ...s are connected Warm air outlets blocked Circulated air intake blocked Check whether the 4 warm air ducts are connected Check individual outlet apertures Remove blockage from circulated air intake Sum...

Page 11: ...istrative regulations of the respective country in which it is used National regulations and laws in Germany for example the End of life Vehicle Regulation must be observed Declaration of conformity T...

Page 12: ...tered see Truma Service Booklet or www truma com In order to avoid delays please have the unit model and factory number ready see type plate Veuillez vous adresser au centre de SAV Truma ou un de nos...

Reviews: