Control panels CP (E) classic

Table of Contents

Symbols used  ......................................................................  14

Intended use

  .....................................................................  14

Operating instructions

Safety instructions

  ...........................................................  15

Display and control panels

  .............................................  15

Control panel – CP classic  ...................................................  15
Power selector switch – CP E classic  ..................................  15

Start-up

  ..............................................................................  16

Hot water mode  ..................................................................  16
Heating and hot water mode  ..............................................  16

Switching off

  ....................................................................  17

Fault

  ....................................................................................  17

Gas or diesel mode  ..............................................................  17
Electrical mode  ....................................................................  18
Mixed mode  ........................................................................  18

Accessories

  .......................................................................  18

Troubleshooting guide (Combi Gas heating system)

  .  19

Troubleshooting guide (Combi Diesel heating system)

  .   21

Technical data

  ...................................................................  23

Maintenance

  .....................................................................  23

Disposal

  .............................................................................  23

Declaration of conformity

  ...............................................  23

Installation instructions

Safety instructions

  ...........................................................  23

Scope of delivery

  ..............................................................  23

Assembly

  ...........................................................................  24

Symbols used

The unit must only be installed and repaired by an 
expert.

Note containing information and tips.

Please pay attention to the ESD regulations! 
 Electrostatic charge can destroy the electronics. 

 Ensure that potential compensation is present before touch-
ing the electronics.

Intended use

Control panel – CP classic

The room temperature and the water temperature can be set 
at a Truma Combi (E) heating system using the control panel. 

Power selector switch – CP E classic

It is possible to choose between gas, diesel and/or electrical 
energy at a Truma Combi (E) heating system (with heating 
elements for electrical mode) using the power selector switch. 
The CP classic control panel is also required.

The control panels are intended for installation in caravans 
and motor homes. Installation in boats is not permitted.

Summary of Contents for CP classic

Page 1: ...hren Operating instructions Page 13 Installation instructions Page 22 To be kept in the vehicle Mode d emploi Page 24 Instructions de montage Page 33 garder dans le v hicule Istruzioni per l uso Pagi...

Page 2: ...23 Assembly 24 Symbols used The unit must only be installed and repaired by an expert Note containing information and tips Please pay attention to the ESD regulations Electrostatic charge can destroy...

Page 3: ...ing or with drained water system Operating instructions e Heating and hot water mode heating with water temperature monitoring f Rotary switch Off g Yellow LED lit Boiler heat up phase yellow LED flas...

Page 4: ...he yellow LED o at the power selector switch indicates that the unit is operating with 230 V Heating with water temperature monitoring Move rotary switch on control panel to On position e Set the rota...

Page 5: ...elect the required operating level according to the tempera ture difference between the setting on the control panel and the current room temperature Once the room temperature selected on the control...

Page 6: ...ow LED o on the power selector switch illuminates and the red LED h or the yellow LED g on the control panel flashes Possible causes can be found in the troubleshooting guide If the flame goes out dur...

Page 7: ...the heating system does not operate The temperature setting on the control panel is lower than the room temperature Select higher room temperature at the control panel After switching on the heating...

Page 8: ...heck gas supply and open valves Gas cylinder empty Replacing a gas cylinder After operating for a longer pe riod of time the heating system switches to failure Gas pressure regulation system iced up U...

Page 9: ...th 5 Hz after the heating system has been switched off After running is active to reduce the temperature of the unit No fault after run switches itself off after max 5 minutes Red LED flashes 6 x Lack...

Page 10: ...s are connected Warm air outlets blocked Circulated air intake blocked Check whether the 4 warm air ducts are connected Check individual outlet apertures Remove blockage from circulated air intake Sum...

Page 11: ...istrative regulations of the respective country in which it is used National regulations and laws in Germany for example the End of life Vehicle Regulation must be observed Declaration of conformity T...

Page 12: ...tered see Truma Service Booklet or www truma com In order to avoid delays please have the unit model and factory number ready see type plate Veuillez vous adresser au centre de SAV Truma ou un de nos...

Reviews: