Technical data

Operating voltage

DC voltage 8 – 16 V 

Ambient temperature 

-20 °C to +60 °C

Front panel

Plastic

Width

190 mm 

Height

110 mm

Depth

29 mm

Cutout dimensions

165 x 90 mm

Weight

170 g

The right to effect technical modifications is reserved!

Trouble-shooting list

Fault

Rectification / Cause

Clock is not shown

Set clock

Activated timer is not shown 
any more 

Power supply was 
interrupted

Room temperature is 
not shown

Heater not active

Device does not react 
any more

Interrupt power supply for 
10 seconds

Heater / display does 
not react

Check 12 V supply voltage

If these measures do not rectify the problem, please contact 
the next Truma Service point (see Truma service book or 
www.truma.com).

Summary of Contents for CP 25-UK

Page 1: ...CP 25 UK Operating instructions Page 2 Installation instructions Page 8 To be kept in the vehicle...

Page 2: ...r over Always position the cables to ensure they do not pose a tripping hazard Do not expose electrical devices to rain Do not operate electrical devices in damp or wet environ ments Do not operate el...

Page 3: ...4 E 6 E The device is designed to be installed in caravans and motorcaravans Initial operation or activation after a power cut After the operating voltage has been connected the unit will beep and th...

Page 4: ...r is on Green LED flashes when the heater is after running Red LED shines when there is a malfunction Manual mode In manual mode the heater is controlled via the 4 keys below the display It is not nec...

Page 5: ...ll not function Water temperature When the menu is selected the yellow LED shines During the heating up phase the set water temperature flash es in the main screen Use key or to select the water tempe...

Page 6: ...t start time Stop Set stop time Water Set water temperature Temp Set room temperature The timer settings can be made every day until the timer is switched off If the room or water tempera ture is chan...

Page 7: ...rouble shooting list Fault Rectification Cause Clock is not shown Set clock Activated timer is not shown any more Power supply was interrupted Room temperature is not shown Heater not active Device do...

Page 8: ...that is protected from damp and wet Prepare an installation opening for the display 190 max 4 165 90 110 6 5 13 5 Dimensions in mm Connect the cable TIN Bus to the display and lead toward the heater...

Page 9: ...9 Press the frame of the panel until it clicks into position The right to effect technical modifications is reserved...

Page 10: ......

Page 11: ......

Page 12: ...ax 01283 58 60 29 sales trumauk com www trumauk com 34020 98600 01 07 2011 In Germany always notify the Truma Service Centre if problems are encountered in other countries the relevant service should...

Reviews: