Truma CP 25-UK Operating Instructions Manual Download Page 8

8

The installation in the vehicle must comply with the  technical 
and administrative provisions of the respective country in 
which it is used (e.g. EN 1648, VDE 0100-721). National regu-
lations and guidelines must be observed.

In other countries always observe the respectively valid 
regulations.

Panel

Install the panel in a place that is protected from damp and wet.

Prepare an installation opening for the display. 

190

max. 4

165 

90

110

6.5

13.5

Dimensions in mm.

Connect the cable (TIN-Bus) to the display and lead toward 
the heater.
Connect the 12 V plug and connect with the 12 V operating 
voltage. Secure the plus cable with a 1 A fuse. 
Connect GSM module (optional). The heater can be 
switched on remotely via the GSM module.

2 x TIN-Bus

+

-

12 V

GSM

View from the back

Attach the panel with 4 screws.

+

-

2 x TIN-Bus

GSM

View from the front

Installation instructions

Summary of Contents for CP 25-UK

Page 1: ...CP 25 UK Operating instructions Page 2 Installation instructions Page 8 To be kept in the vehicle...

Page 2: ...r over Always position the cables to ensure they do not pose a tripping hazard Do not expose electrical devices to rain Do not operate electrical devices in damp or wet environ ments Do not operate el...

Page 3: ...4 E 6 E The device is designed to be installed in caravans and motorcaravans Initial operation or activation after a power cut After the operating voltage has been connected the unit will beep and th...

Page 4: ...r is on Green LED flashes when the heater is after running Red LED shines when there is a malfunction Manual mode In manual mode the heater is controlled via the 4 keys below the display It is not nec...

Page 5: ...ll not function Water temperature When the menu is selected the yellow LED shines During the heating up phase the set water temperature flash es in the main screen Use key or to select the water tempe...

Page 6: ...t start time Stop Set stop time Water Set water temperature Temp Set room temperature The timer settings can be made every day until the timer is switched off If the room or water tempera ture is chan...

Page 7: ...rouble shooting list Fault Rectification Cause Clock is not shown Set clock Activated timer is not shown any more Power supply was interrupted Room temperature is not shown Heater not active Device do...

Page 8: ...that is protected from damp and wet Prepare an installation opening for the display 190 max 4 165 90 110 6 5 13 5 Dimensions in mm Connect the cable TIN Bus to the display and lead toward the heater...

Page 9: ...9 Press the frame of the panel until it clicks into position The right to effect technical modifications is reserved...

Page 10: ......

Page 11: ......

Page 12: ...ax 01283 58 60 29 sales trumauk com www trumauk com 34020 98600 01 07 2011 In Germany always notify the Truma Service Centre if problems are encountered in other countries the relevant service should...

Reviews: