8
The installation in the vehicle must comply with the technical
and administrative provisions of the respective country in
which it is used (e.g. EN 1648, VDE 0100-721). National regu-
lations and guidelines must be observed.
In other countries always observe the respectively valid
regulations.
Panel
Install the panel in a place that is protected from damp and wet.
Prepare an installation opening for the display.
190
max. 4
165
90
110
6.5
13.5
Dimensions in mm.
–
Connect the cable (TIN-Bus) to the display and lead toward
the heater.
Connect the 12 V plug and connect with the 12 V operating
voltage. Secure the plus cable with a 1 A fuse.
Connect GSM module (optional). The heater can be
switched on remotely via the GSM module.
2 x TIN-Bus
+
-
12 V
GSM
View from the back
Attach the panel with 4 screws.
+
-
2 x TIN-Bus
GSM
View from the front
–
–
–
–
Installation instructions