User Manual
7
TENCHNICAL PARAMETERS
(tested under the conditions of ambient temperature 15
℃
and water temperature 10
Model
Ice making capacity
(Kg/24h)
Power input(W)
Refrigerant
R134a (g)
Dimensions(mm)
IF-20
≤
20
280
75
330X470X605
IF-50
≤
50
380
115
400X543X700
IF-120
≤
120
550
155
500X610X950
IF-200
≤
200
1040
280
680X740X1100
The specifications are subject to be changed without notice. Please check the nameplate for
sure.
TROUBLE AND SHOOTING
(FOR REFERENCE OF USERS AND TECHNICIANS)
TROUBLE
CAUSE
REMEDY
The flake ice maker
does not work.
1. The voltage is lower than
the lower limitation
2. The ambient temperature
is too low (Lower than 10
℃
)
1. Stop the ice maker and
restart it until the voltage
is normal.
2. Try again when the ambient
temperature higher than 10
℃
.
Water shortage
indicator light on.
1. Water shortage from the
water supply system.
2. Water valve damage.
3. Tap water pressure too low.
1. Check the water supply. If it
is OK, restart the maker.
2. Check the water valve.
3. Be sure the tap water press-
ure is higher than 1.5 bar.
Compressor does
not work.
1. Water shortage.
2. Ice full.
1. Check the water supply
system (water valve and water
supply tube).
2. Take off some ice.
Compressor works,
but no ice is made.
1. Refrigerant leakage.
2. The refrigerating system
is blocked.
1. Recharge the refrigerant and
check the leakage again.
2. Charging N2 to check whet-
her the sysem is blocked and
replace the filter.
3. Check whether the fan is
running.
Water shortage
indicator and ice
full indicator are
glittering at the
same time.
If water inlet jam or running
failure because of low
environmental temperature.
Stop the machine until the
temperature reach 10
℃
or
repair it by authorized
service people.