CAPACITIVE TOUCH SERIES

MODEL

TX1000 OF220-V2 1CE

TX1000 OF220-V2 1CK

CAPACITIVE TOUCH SERIES

APPLICATIONS

TX1000 Series is touch pad thermostat with many variants suitable for 2-pipe cooling & heating fan coil units and DX single stage
compressor units. Available in basic standalone and Modbus communicating variants.

Options of back-light selection in sky blue and black VA LCD. Fitted with built-in NTC 10K sensor and optional humidity sensor.
Several addon functions like remote sensor, key card can be chosen as per site requirements.

FEATURES

Modern touch pad design

residential buildings

Applicable for 2-pipe FCU 
cooling&heating, Simple on-off valve 
or compressor

♦ 

Black LCD and Sky-blue LCD 
display selectable

Special colors casing upon request  
with RAL number can be provided

Both room and Set-point display

Manual & Automatic fan functions

User setting can be kept during   

Fan load 5A resistive and inductive  
of 3A

Big LCD with English display

Temperature unit C&F 

Regular color available in Black
and White body

EC motor variants available

Fits in 75mmx75mm electrical 
junction box

Real Time clock with infinite life 
battery backup

TX1000 OF024-V2 1C

1

Summary of Contents for TX1000 Series

Page 1: ...e sensor key card can be chosen as per site requirements FEATURES Modern touch pad design residential buildings Applicable for 2 pipe FCU cooling heating Simple on off valve or compressor Black LCD an...

Page 2: ...f valve or compressor Suitable Valve 2 line 3 line valve Relative Humidity 10 90 Installed on 75mm x 75mm box ORDERING PART NUMBERS TX1000 OF220 V21CE 85 240VAC 2 PIPE SINGLE STAGE 2 PIPE SINGLE STAGE...

Page 3: ...ault value is 18 C The value can be changed in ISU mode with step of 1 C For cooling mode if energy saving function is enabled the set point will be changed to remote setback cooling set point The ran...

Page 4: ...ILABLE DEFAULT 1 MODE BUTTON IS LOCKED OUT 2 FAN AND MODE BUTTON ARE LOCKED OUT 3 ALL BUTTONS ARE LOCKED 5 REMOTE SETBACK ENABLE METHOD NO HOTEL CARD NO NC HOTEL CARD NC BU BUTTON DEFAULT 6 FREEZE PRO...

Page 5: ...OWER OFF WHILE ELECTRIFIED THE THERMOSTAT WILL BE OFF SU ON USER SETTING WILL BE KEPT WHEN POWER OFF WHILE ELECTRIFIED THE THERMOSTAT WILL BE ON DEFAULT IS OF 21 22 23 24 25 26 20 BACK LIGHT SETTINGS...

Page 6: ...PRESSOR OPEN 6 VALVE COMPRESSOR CLOSE 7 COM FOR EXTERNAL SENSOR 8 NEUTRAL IN 9 L FM FH FL NO NC COM N AI EXTERNAL SENSOR TERMINALS NO 1 LIVE IN 3 MEDIUM SPEED FAN HIGH SPEED FAN 4 LOW SPEED FAN 2 DESC...

Page 7: ...n Wait five minutes for the cooling system to respond The Mode button does not work Check whether the Fan mode is set to Auto Check whether the heating or cooling system works well Check whether the k...