A
actsGroupValid OBJECT-TYPE
SYNTAX
INTEGER { (0..1) }
ACCESS
read-only
STATUS
mandatory for ACTS capable units
7.9.2
A test flag indicating if data contained in this SNMP ACTS group is valid or not. This flag
equals 1 when ACTS is used as the time synchronization source and 0 for all other
sources.
::= { acts 1 }
actsBaudRate OBJECT-TYPE
SYNTAX
INTEGER { (300), (1200) }
ACCESS
read-only
STATUS
mandatory for ACTS capable units
7.9.3
Indicates the baud rate setting for the ACTS modem. The ACTS dial-up service accepts
300 or 1200 baud. Note: this is a rare case where faster is not better and 300 baud
yields the best time accuracy.
::= { acts 2 }
actsFailRedial OBJECT-TYPE
SYNTAX
INTEGER { (0..+9999) }
ACCESS
read-only
STATUS
mandatory for ACTS capable units
7.9.4
When the dial-up session fails to connect this is the time in seconds to wait to try again.
::= { acts 3 }
actsMaxCallPeriod OBJECT-TYPE
SYNTAX
INTEGER { (0..+999) }
ACCESS
read-only
STATUS
mandatory for ACTS capable units
7.9.5
This is the maximum time in hours the ACTS unit will wait between successful calls to the
ACTS service.
::= { acts 4 }
actsPhoneNum OBJECT-TYPE
SYNTAX
DisplayString (SIZE (0..25))
ACCESS
read-only
STATUS
mandatory