True T-12FG Installation Manual Download Page 8

............ www.truemfg.com ............

True Food Service Equipment, Inc.

6

6

INSTALLATION / OPERATION INSTRUCTIONS

P

A. 

Set unit in its final location. Be sure there is adequate 

ventilation in your room. Under extreme heat 

conditions, (100°F+, 38°C+), you may want to install 

an exhaust fan.

WARNING

Warranty is void if ventilation is insufficient.

B. 

Proper leveling of your TRUE cooler is critical to 

operating success (for non-mobile models). Effective 

condensate removal and door operation will be 

effected by leveling.

C. 

The cooler should be leveled front to back and side 

to side with a level. 

D. 

Ensure that the drain hose or hoses are positioned in 

the pan.

E. 

Free plug and cord from inside the lower rear of the 

cooler (do not plug in).

F. 

The unit should be placed close enough to the 

electrical supply so that extension cords are never 

used.

WARNING

Cabinet warranties are void if OEM power cord is tampered 

with. TRUE will not warranty any units that are connected to 

an extension cord. 

LEVELING

LOCATING

REMOTE UNITS (This section applies to remotes only!)

•  Remote cabinets must be ordered as remote.  

 

  We do not recommend converting from a  

 

  standard self contained to remote system.
•  All remote cabinets must be hard wired.
•  No castors available.
•  All remote cabinets come standard using 404A    

  refrigerant.
•  All remote units come standard with expansion    

  valve, liquid line solenoid, heated condensate  

 

  pan, and defrost timer when applicable.

•   Contact TRUE Technical Service for BTU  

 

  requirements.
•  No wiring necessary between cabinet and   

 

  condensing unit.
•  All remote condensing units purchased from  

 

  TRUE are 208/230 volts single phase.

If you have any questions regarding this section, please 

call TRUE at 1-(800)-325-6152.

A.

  Remove louver from the front of cabinet (see page 17 for 

louver grill removal / reinstallation) and backguard (if 

applicable) from rear of cabinet.

B.

  Skid bolts are located in each of 4 corners inside cabinet 

bottom. (See photo A).

C.

  Remove skid bolts. (See photo B).

D.

  Cut straps if applicable. (See photo C).

E.

  Carefully lift cabinet off of skid.

F. 

Applicance tested according to the climate classes 5 and 7 

for temperature and relative humidity.

Removing skid from bottom  
of cabinet.

A

B

C

Summary of Contents for T-12FG

Page 1: ...eld Troubleshooting Freezer Units Only 25 26 Light Cover Install for T 12FG 27 Maintenance Care Cleaning Cleaning Condenser Coil 28 29 Stainless Steel Equipment Care Cleaning 30 31 Light Bulb Replacem...

Page 2: ...www truemfg com True Food Service Equipment Inc...

Page 3: ...ervice personnel Do not puncture refrigerant tubing Caution Risk of fire or explosion Flammable refrigerant used Consult repair manual owner s guide before attempting to service this product All safet...

Page 4: ...www truemfg com True Food Service Equipment Inc 2 2...

Page 5: ...helves in place so that children may not easily climb inside Refrigerant Disposal Your old refrigerator may have a cooling system that uses Ozone Depleting chemicals If you are throwing away your old...

Page 6: ...N At Receptacle Box 1 Turn breaker off 2 Disconnect all wires from receptacle 3 Insulate red wire tape or wire nut 4 Connect black white and green wires to 3 prong plug NEMA 5 20R per instructions on...

Page 7: ...is recommended for uncrating the unit A Remove the outer packaging cardboard and bubbles or styrofoam corners and clear plastic Inspect for concealed damage Again immediately file a claim with the fre...

Page 8: ...G REMOTE UNITS This section applies to remotes only Remote cabinets must be ordered as remote We do not recommend converting from a standard self contained to remote system All remote cabinets must be...

Page 9: ...inst the lower rail assembly see image 4 5 The bearing race on the castor or the top edge of the leg must make firm contact with the rail Unit leveling Four leveling shims have been provided for level...

Page 10: ...n with the hand brakes WARNING Unit may tip forward if procedure F is not strictly followed G Units final location should be adequately ventilated Conditions where heat exceeds 100 F require an exhaus...

Page 11: ...ons Doors can not be removed unless placed in specific locations stated in these instructions STEP 2 Two Door Units Slide the front door so it is centered on the cabinet The door can not be removed un...

Page 12: ...10 8 6 6 6 5 5 4 4 3 2 40 10 8 8 6 6 5 5 4 4 3 2 2 45 10 8 6 6 6 5 4 4 3 3 2 1 50 10 8 6 6 5 4 4 3 3 2 1 1 Wire Gauge for 2 Voltage Drop in Supply Circuits 230 Volts Distance In Feet To Center of Load...

Page 13: ...vel side to side and front to back Place a carpenter s level in the interior floor in four places A Position level in the inside floor of the unit near the doors Level should be parallel to cabinet fr...

Page 14: ...N Before loading product we recommend you run your TRUE unit empty for two to three days This allows you to be sure electrical wiring and installation are correct and no shipping damage has occurred R...

Page 15: ...www truemfg com True Food Service Equipment Inc 13 13 IF YOUR CABINET IS BUILT WITH THIS TEMPERATURE CONTROL PLEASE SEE THE FOLLOWING INSTRUCTIONS...

Page 16: ...temperature that will start the compressor Example If the Set Point is 9 F 23 C and the Differential is 10 F 5 C Set Point 9 F 10 Differential 1 F Or Set Point 23 C 5 Differential 18 C The compressor...

Page 17: ...lock settings If no appears the controller is unlocked If yes appears the controller is locked See images 3 and 4 C Once the lock setting has been set correctly release the info button Wait 5 seconds...

Page 18: ...interior sign lights by the interior door switch depress the rocker switch to the ON position Light Switch is located on inside top right of the ceiling ON Position Solid Door models lights are contr...

Page 19: ...ntrol Icons May need to unlock control WHY THE SET POINT IS THE TEMPERATURE AT WHICH THE COMPRESSOR WILL SHUT OFF Please note that the set point IS NOT the cabinet holding temperature HOW A To see the...

Page 20: ...the Manual Defrost button until dEF appears B REAL TIME CLOCK RTC If controller is preprogrammed for RTC press the and hold the Manual Defrost button for 5 seconds until dh1 appears Release the Manual...

Page 21: ...he set point press and hold the info button and the stand by button at the same time ScL will appear See image 1 B Push the up button until dFt appears See image 2 C Press and hold the info button to...

Page 22: ...www truemfg com True Food Service Equipment Inc 20 20 DISPLAY...

Page 23: ...228 DDY OS2 X 1 8 75 167 1 925 FID T3 80 176 1 669 FDD X 32 1 8 OS3 X 1 8 85 185 1 452 FTO TLD 90 194 1 268 FCM SIM 95 203 1 145 FDT X 1 8 ADR 100 212 0 974 FDH X 1 8 105 221 0 858 FT1 110 230 0 758...

Page 24: ...r housing along the interior ceiling Shelf Clip Shelf Shelf T Series GDM 5 Airflow Guard Pillaster WARNING Do not use pliers or any crimping tools when installing shelf clips Altering shelf clips in a...

Page 25: ...23F WARNING High usage high temperature and high humidity may require additional defrost settings per day Once clock is set grill is correctly reinstalled cabinet can be plugged in T 19F T 19FZ T 23F...

Page 26: ...ssary to warm up the set points To make the adjustment insert the appropriate tool in each adjustment screw and turn 1 4 of a revolution clockwise to the right This procedure will adjust both the cut...

Page 27: ...ually increase to infinity b If there is no movement of the ohmmeter indicator an open circuit is indicated c If the ohmmeter indicator moves to zero and remains there or on a low resistance reading a...

Page 28: ...the nameplate rating may indicate a broken suction reed or broken connecting rod in the compressor DIAGNOSIS AND REPLACEMENT OF FREEZER CABINET COMPONENTS 1 Defrost Time Clock A Check timer motor to b...

Page 29: ...rubber gasket and push rubber over the top lip of the lamp shield STEP 3 Be sure lamp cover is seated properly in rubber gasket IMPORTANT Before replacing light cover turn cabinet on and wait until i...

Page 30: ...anchoring compressor assembly to frame rails and carefully slide out tube connections are flexible Step 4 Clean off accumulated dirt from the condenser coil and the fan with a stiff bristle brush Step...

Page 31: ...abinet grill to expose the Condenser The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capacity Do not place filter...

Page 32: ...plastic scouring pad or soft cloth when you cannot see the grain 3 Use alkaline alkaline chlorinated or non chloride containing cleaners While many traditional cleaners are loaded with chlorides the...

Page 33: ...ituations environments of stainless steel A Soap ammonia and detergent medallion applied with a cloth or sponge can be used for routine cleaning B Arcal 20 Lac O Nu Ecoshine applied provides barrier f...

Page 34: ...must also be the same capacity as the drier being replaced 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained All claims for labo...

Reviews: