True T-12FG Installation Manual Download Page 24

............ www.truemfg.com ............

True Food Service Equipment, Inc.

22

22

SHELVING INSTALLATION / OPERATION & 

LIGHT SWITCH LOCATION

INSTALLATION / OPERATION INSTRUCTIONS

SHELF & ORGANIZER INSTALLATION:
Step 1
A.

  Hook shelf clips onto shelf standards. (see illustration).

B.

   Position all four shelf clips equal in distance from the 

 

floor for flat shelves.

WIRE SHELVES

 

Wire shelves are oriented so that cross support bars are facing down.

NOTE

T-Series models include an airflow guard on the rear of shelves to 

maintain an air space at the rear of the cabinet. (see illustration).

Step 2

Place shelves on shelf clips making sure all corners are seated 

properly.

LIGHT SWITCH LOCATION:

Light switch location depends upon the T-Series model. Most 

T-Series models will have the light switch located inside the unit on 

the right side of the ceiling. Most instances the switch is located next 

to the temperature control. Some models have the switch located on 

the right side of the evaporator housing along the interior ceiling. 

Shelf

Clip

Shelf

Shelf

T-Series

& GDM-5

Airflow

Guard

Pillaster

WARNING

Do not use pliers or any crimping tools when 

installing shelf clips. Altering shelf clips in any 

way can lead to shelving instability. 

For Proper Shelf Clip Installation Please 

Read The Following Instructions.

Step 1

Install the top tab of the shelf clip into the 

proper hole. Push up on the bottom of the 

clip. (See image 1).

Step 2

Bottom tab of the shelf clip will fit tightly. 

You may need to squeeze or twist the 

bottom of the shelf clip to install. (See 

image 2 & 3).

Step 3

After installation, the shelf clip will fit snug 

into the shelf standard. The shelf clip should 

not be loose or able to wiggle out of the 

shelf standard.

Shelf Installation Tips
1

.    Install all the shelf clips before installing 

the shelves.

2

.    Start at the bottom in terms of shelf 

installation and work your way up.

3

.    Always lay the back of each shelf down 

on the rear clips before the front.

(Installing top tab of shelf clip)

(Installing bottom of the shelf clip)

You may need to squeeze or twist the bottom 
of the shelf clip to install)

(Shelf clip installation complete)

1

2

4

3

Summary of Contents for T-12FG

Page 1: ...eld Troubleshooting Freezer Units Only 25 26 Light Cover Install for T 12FG 27 Maintenance Care Cleaning Cleaning Condenser Coil 28 29 Stainless Steel Equipment Care Cleaning 30 31 Light Bulb Replacem...

Page 2: ...www truemfg com True Food Service Equipment Inc...

Page 3: ...ervice personnel Do not puncture refrigerant tubing Caution Risk of fire or explosion Flammable refrigerant used Consult repair manual owner s guide before attempting to service this product All safet...

Page 4: ...www truemfg com True Food Service Equipment Inc 2 2...

Page 5: ...helves in place so that children may not easily climb inside Refrigerant Disposal Your old refrigerator may have a cooling system that uses Ozone Depleting chemicals If you are throwing away your old...

Page 6: ...N At Receptacle Box 1 Turn breaker off 2 Disconnect all wires from receptacle 3 Insulate red wire tape or wire nut 4 Connect black white and green wires to 3 prong plug NEMA 5 20R per instructions on...

Page 7: ...is recommended for uncrating the unit A Remove the outer packaging cardboard and bubbles or styrofoam corners and clear plastic Inspect for concealed damage Again immediately file a claim with the fre...

Page 8: ...G REMOTE UNITS This section applies to remotes only Remote cabinets must be ordered as remote We do not recommend converting from a standard self contained to remote system All remote cabinets must be...

Page 9: ...inst the lower rail assembly see image 4 5 The bearing race on the castor or the top edge of the leg must make firm contact with the rail Unit leveling Four leveling shims have been provided for level...

Page 10: ...n with the hand brakes WARNING Unit may tip forward if procedure F is not strictly followed G Units final location should be adequately ventilated Conditions where heat exceeds 100 F require an exhaus...

Page 11: ...ons Doors can not be removed unless placed in specific locations stated in these instructions STEP 2 Two Door Units Slide the front door so it is centered on the cabinet The door can not be removed un...

Page 12: ...10 8 6 6 6 5 5 4 4 3 2 40 10 8 8 6 6 5 5 4 4 3 2 2 45 10 8 6 6 6 5 4 4 3 3 2 1 50 10 8 6 6 5 4 4 3 3 2 1 1 Wire Gauge for 2 Voltage Drop in Supply Circuits 230 Volts Distance In Feet To Center of Load...

Page 13: ...vel side to side and front to back Place a carpenter s level in the interior floor in four places A Position level in the inside floor of the unit near the doors Level should be parallel to cabinet fr...

Page 14: ...N Before loading product we recommend you run your TRUE unit empty for two to three days This allows you to be sure electrical wiring and installation are correct and no shipping damage has occurred R...

Page 15: ...www truemfg com True Food Service Equipment Inc 13 13 IF YOUR CABINET IS BUILT WITH THIS TEMPERATURE CONTROL PLEASE SEE THE FOLLOWING INSTRUCTIONS...

Page 16: ...temperature that will start the compressor Example If the Set Point is 9 F 23 C and the Differential is 10 F 5 C Set Point 9 F 10 Differential 1 F Or Set Point 23 C 5 Differential 18 C The compressor...

Page 17: ...lock settings If no appears the controller is unlocked If yes appears the controller is locked See images 3 and 4 C Once the lock setting has been set correctly release the info button Wait 5 seconds...

Page 18: ...interior sign lights by the interior door switch depress the rocker switch to the ON position Light Switch is located on inside top right of the ceiling ON Position Solid Door models lights are contr...

Page 19: ...ntrol Icons May need to unlock control WHY THE SET POINT IS THE TEMPERATURE AT WHICH THE COMPRESSOR WILL SHUT OFF Please note that the set point IS NOT the cabinet holding temperature HOW A To see the...

Page 20: ...the Manual Defrost button until dEF appears B REAL TIME CLOCK RTC If controller is preprogrammed for RTC press the and hold the Manual Defrost button for 5 seconds until dh1 appears Release the Manual...

Page 21: ...he set point press and hold the info button and the stand by button at the same time ScL will appear See image 1 B Push the up button until dFt appears See image 2 C Press and hold the info button to...

Page 22: ...www truemfg com True Food Service Equipment Inc 20 20 DISPLAY...

Page 23: ...228 DDY OS2 X 1 8 75 167 1 925 FID T3 80 176 1 669 FDD X 32 1 8 OS3 X 1 8 85 185 1 452 FTO TLD 90 194 1 268 FCM SIM 95 203 1 145 FDT X 1 8 ADR 100 212 0 974 FDH X 1 8 105 221 0 858 FT1 110 230 0 758...

Page 24: ...r housing along the interior ceiling Shelf Clip Shelf Shelf T Series GDM 5 Airflow Guard Pillaster WARNING Do not use pliers or any crimping tools when installing shelf clips Altering shelf clips in a...

Page 25: ...23F WARNING High usage high temperature and high humidity may require additional defrost settings per day Once clock is set grill is correctly reinstalled cabinet can be plugged in T 19F T 19FZ T 23F...

Page 26: ...ssary to warm up the set points To make the adjustment insert the appropriate tool in each adjustment screw and turn 1 4 of a revolution clockwise to the right This procedure will adjust both the cut...

Page 27: ...ually increase to infinity b If there is no movement of the ohmmeter indicator an open circuit is indicated c If the ohmmeter indicator moves to zero and remains there or on a low resistance reading a...

Page 28: ...the nameplate rating may indicate a broken suction reed or broken connecting rod in the compressor DIAGNOSIS AND REPLACEMENT OF FREEZER CABINET COMPONENTS 1 Defrost Time Clock A Check timer motor to b...

Page 29: ...rubber gasket and push rubber over the top lip of the lamp shield STEP 3 Be sure lamp cover is seated properly in rubber gasket IMPORTANT Before replacing light cover turn cabinet on and wait until i...

Page 30: ...anchoring compressor assembly to frame rails and carefully slide out tube connections are flexible Step 4 Clean off accumulated dirt from the condenser coil and the fan with a stiff bristle brush Step...

Page 31: ...abinet grill to expose the Condenser The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capacity Do not place filter...

Page 32: ...plastic scouring pad or soft cloth when you cannot see the grain 3 Use alkaline alkaline chlorinated or non chloride containing cleaners While many traditional cleaners are loaded with chlorides the...

Page 33: ...ituations environments of stainless steel A Soap ammonia and detergent medallion applied with a cloth or sponge can be used for routine cleaning B Arcal 20 Lac O Nu Ecoshine applied provides barrier f...

Page 34: ...must also be the same capacity as the drier being replaced 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained All claims for labo...

Reviews: