ADA HEIGHT INSTALL GUIDE
TEC_TM_120 REV. B
02/02/2022
Page 65 of 74
A D J U S T M E N T S , S E R V I C I N G & R E P L A C I N G C O M P O N E N T S
RE VERSING DOOR
REQUIRED TOOLS
• 1/8" Hex Head Allen Wrench
• Drill (Optional)
PROCEDURE
1. Loosen the hinge bolts and remove the door
See fig. 1.
NOTE: DO NOT REMOVE THE HINGES FROM
THE DOOR.
2. Move the remaining hardware to the opposite
corners. See fig. 2.
NOTE: THE DOOR LOCK POSITION IS
DIFFERENT FOR E ACH SIDE.
LEF T-HINGED: BOT TOM RIGHT CORNER;
RIGHT-HINGED: UPPER LEF T CORNER.
3. Rotate the door 180° and secure it to the cabinet.
See figs. 3 and 4.
4. Verify the door closes correctly and the gasket
seals without gaps.
FIG. 1.
Do not remove the hinge bolts.
FIG. 2.
Be sure to move the hardware to the opposite corners.
FIG. 3.
Rotate the door 180
°
and install.
FIG. 4.
Completed installation.
180°