M A I N T E N A N C E , C A R E & C L E A N I N G
WARNING
– Electrical shock or burn
hazard. Unplug the unit or turn off the
power supply before proceeding.
DO NOT
clean appliance with a pressure
washer or hose.
ATTENTION
– Risque d’électrocution ou
de brûlure. Débranchez l’appareil ou
coupez l’alimentation électrique avant
de continuer. Ne nettoyez pas l’appareil
avec un nettoyeur haute pression ou un
tuyau.
CAUTION
– Risk of eye injury from
debris. Eye protection is recommended.
ATTENTION
– Les ailettes sont
coupantes. Soyez prudent pour éviter
les lésions oculaires. Une protection des
yeux est recommandée.
CAUTION
– Coil fins are sharp. Gloves
are recommended.
ATTENTION
– Les ailettes de la bobine
sont tranchantes. Les gants sont
recommandés.
REQUIRED TOOLS
Required tools include (but may not be limited to) the
following:
• Gloves
• Eye Protection
• Stiff Bristle Brush
• Vacuum Cleaner
• Flashlight
• Tank of Compressed Air
PROCEDURE
1. Remove the kickplate. See fig. 1.
2. With a stiff bristle brush, carefully clean
accumulated dirt from the front coil fins.
3. With the dirt removed from the surface of the coil,
use a flashlight to verify you can see through the
coil and observe the condenser fan blade spinning.
See fig. 3.
4. If the view is clear, reinstall the kickplate, restore
power, and verify correct operation.
5. If the view is not clear, gently blow compressed air
or CO
2
through the coil until it is clean.
6. Carefully vacuum any dirt around the condensing
unit area.
7. Reinstall the kickplate, restore power, and verify
correct operation.
CAUTION – TAK E CARE DURING OPER ATION, MAINTENANCE, OR REPAIRS TO AVOID CUTS OR
PINCHING FROM ANY CABINET PART/ COMPONENT.
AT TENTION – LORS DE L’UTILISATION, DE L’ENTRETIEN OU DES RÉPAR ATIONS, IL FAUT
PRENDRE SOIN D’ÉVITER LES COUPURES ET LES PINCEMENTS POUVANT SURVENIR AU
CONTACT DES PIÈCES OU DES COMPOSANTES DE L’ARMOIRE.
CONDENSER COIL CLE ANING
Keeping the condenser coil clean minimizes required servicing and lowers electrical cost. Warranty does not cover
cleaning the condenser coil.
Summary of Contents for RESIDENTIAL ADA HEIGHT TUBADA-24-R/L-RG-A-S
Page 2: ...TRUE RESIDENTIAL TEC_TM_102 REV B 02 02 2022 THANK YOU FOR YOUR PURCHASE...
Page 6: ...TRUE RESIDENTIAL TEC_TM_102 REV B 02 02 2022 Page 6 of 74 N O T E S...
Page 14: ...TRUE RESIDENTIAL TEC_TM_102 REV B 02 02 2022 Page 14 of 74 N O T E S...
Page 38: ...TRUE RESIDENTIAL TEC_TM_102 REV B 02 02 2022 Page 38 of 74 N O T E S...
Page 62: ...TRUE RESIDENTIAL TEC_TM_102 REV B 02 02 2022 Page 62 of 74 N O T E S...
Page 71: ...ADA HEIGHT INSTALL GUIDE TEC_TM_120 REV B 02 02 2022 Page 71 of 74 N O T E S...