CHAPTER 7: ADDITIONAL INFORMATION
TRUEfitness.com / 800.426.6570 / 636.272.7100
46
TROUBLESHOOTING GUIDE (continued):
Fault IN02: Incline Out
of Range
Incline
Incline value is out of the
calibrated range - does not
occur during calibration
Console displays Fault
Calibration not saved.
Incline disabled.
Power cycle
Check cable
connections
Run incline calibration
Incline Potentiometer
value out of range
Contact dealer or
TRUE service
Fault IN03: Incline Run
Fault
Incline
Incline moving when not
commanded
Console displays Fault
Calibration not saved.
Incline disabled.
Power cycle
Check cable
connections
Run incline calibration
Incline Potentiometer
value out of range
Contact dealer or
TRUE service
Fault IN04: Incline
Max/Min
Incline
Incline value is out of expected
operating range - may indicate
that it is disconnected.
Console displays Fault
Calibration not saved.
Incline disabled.
Power cycle
Check cable
Connections
Run incline calibration
Incline Potentiometer
value out of range
Contact dealer or
TRUE service
Fault D100: Motor
Controller Fault
DC
MCB
Motor Control Board Fault
Motor Control Board
Power cycle
Contact dealer or
TRUE service
Fault D101: Lower
Board Communication
Fault
DC
MCB
Endex did not receive
communication from BB in 18
seconds
Loose Cable
Connection
Power cycle
Check cable
connections
Motor Control Board Contact dealer or
TRUE service
upper display/console
Fault D103: Motor
Controller Fault
DC
MCB
Low Incoming AC Voltage
Low AC Line Voltage
Power cycle
Check AC line voltage
Fault D104: Motor
Controller Fault
DC
MCB
Motor Control Board Fault
Motor Control Board
Power cycle
Contact dealer or
TRUE service
Fault D106: Motor
Controller Fault
DC
MCB
High Incoming AC Voltage
High AC line voltage
Check AC line voltage
Motor Control Board
Power cycle
Contact dealer or
TRUE service
High Belt Deck
Friction
Lubricate treadbelt
Fault D107: Motor
Over Current
DC
MCB
High Incoming AC Voltage
High AC line voltage
Check AC line voltage