CHAPTER 7: ADDITIONAL INFORMATION
TRUEfitness.com / 800.426.6570 / 636.272.7100
47
TROUBLESHOOTING GUIDE (continued):
Fault D108: Motor
Over Current
DC
MCB
High Incoming AC Voltage
High AC line voltage
Check AC line voltage
Motor Control Board
Power cycle
Contact dealer or
TRUE service
High Belt Deck
Friction
Lubricate treadbelt
Fault D109: Motor
Controller Zero
Current
DC
MCB
Low Incoming AC Voltage
Low AC Line Voltage
Power cycle
Contact dealer or
TRUE service
Fault D110: Motor
Controller Overcurrent
DC
MCB
High Incoming AC Voltage
High AC line voltage
Check AC line voltage
Motor Control Board
Power cycle
Contact dealer or
TRUE service
High Belt Deck
Friction
Lubricate treadbelt
Fault D111: Motor
Controller Voltage
Overload
DC
MCB
Low Incoming AC Voltage
Low AC Line Voltage
Power cycle
Check AC line voltage
Contact dealer or
TRUE service
Fault D112: Motor
Controller
Undervoltage
DC
MCB
Low Incoming AC Voltage
Low AC Line Voltage
Power cycle
Check AC line voltage
Contact dealer or
TRUE service
Fault D113: Motor
Controller Control
Fault
DC
MCB
Incline Stall - incline not
moving when commanded
Console displays Fault
Calibration not saved.
Incline disabled.
Power cycle
Check cable
Connections
Run incline calibration
Incline Potentiometer
value out of range
Contact dealer or
TRUE service
Acme Nut Jammed
Motor bearings
Fault D114: Lower
Board Incline Range
Fault
DC
MCB
Incline out of range
Console displays Fault
Calibration not saved.
Incline disabled.
Power cycle
Check cable
connections
Run incline calibration
Incline Potentiometer
value out of range
Contact dealer or
TRUE service