Fault IN04:
Incline Max/Min
Incline
Incline value is out of
expected operating
range - may indicate
that it is disconnected.
Console displays Fault
Calibration not saved.
Incline disabled.
Power cycle
Check cable connections
Run incline calibration
Incline Potentiometer
value out of range
Contact dealer or TRUE service
Fault A101:
Motor Controller
Fault
AC MCB
2.5 VDC Ref Status
Motor Control Board
Power cycle
Contact dealer or TRUE service
Fault A102:
Motor
Controller
Fault
AC MCB 1.65 VDC Ref Status
Motor Control Board
Power cycle
Contact dealer or TRUE service
Fault A103:
Motor
Controller
Fault
AC MCB
Phase B Current
Sensor
Loose Cable
Check cable connections
Motor Control Board Contact dealer or TRUE service
Fault A104:
Motor
Controller
Fault
AC MCB
Phase A Current
Sensor
Loose Cable
Check cable connections
Motor Control Board Contact dealer or TRUE service
Fault A105:
Motor
Controller
Fault
AC MCB Phase C Circuit Open
Loose Cable
Check cable connections
Motor Control Board Contact dealer or TRUE service
Fault A106:
Motor
Controller
Fault
AC MCB Phase B Circuit Open
Loose Cable
Check cable connections
Motor Control Board Contact dealer or TRUE service
Fault A107:
Motor
Controller
Fault
AC MCB Phase A Circuit Open
Loose Cable
Check cable connections
Motor Control Board Contact dealer or TRUE service
Fault A108:
Motor
Controller
Fault
AC MCB
DCLink Bus
Overvoltage (MAX_
VDC1)
Loose Cable
Connection
Power cycle
Check cable connections
Motor Control Board Contact dealer or TRUE service
Fault A109:
Motor
Controller
Fault
AC MCB
Critical DCLink Bus
Overvoltage (MAX_
VDC2)
Loose Cable
Connection
Power cycle
Check cable connections
Motor Control Board Contact dealer or TRUE service
Fault A110:
Motor
Controller
Fault
AC MCB
DCLink Bus Under
Voltage
Line Voltage
Check AC line voltage
Motor Control Board Contact dealer or TRUE service