230 Volts Distance In Feet To Center of Load
Amps 20 30 40 50 60 70 80 90 100 120 140 160
5
14 14 14 14 14 14 14 14 14 14 14 14
6
14 14 14 14 14 14 14 14 14 14 14 12
7
14 14 14 14 14 14 14 14 14 14 12 12
8
14 14 14 14 14 14 14 14 14 12 12 12
9
14 14 14 14 14 14 14 14 12 12 12 10
10
14 14 14 14 14 14 14 12 12 12 10 10
12
14 14 14 14 14 14 12 12 12 10 10 10
14
14 14 14 14 14 12 12 12 10 10 10 8
16
14 14 14 14 12 12 12 10 10 10 8 8
18
14 14 14 12 12 12 10 10 10 8 8 8
20
14 14 14 12 10 10 10 10 10 8 8 8
25
14 14 12 12 10 10 10 10 8 8 6 6
30
14 12 12 10 10 10 8 8 8 6 6 6
35
14 12 10 10 10 8 8 8 8 6 6 5
40
14 12 10 10 8 8 8 6 6 6 5 5
50
12 10 10 8 6 6 6 6 6 5 4 4
60 12
10 8 6 6 6 6 6 5 4 4 3
70 10
10 8 6 6 6 5 5 4 4 2 2
80 10 8 8 6 6 5 5 4 4 3 2 2
90 10 8 6 6 5 5 4 4 3 3 1 1
100 10 8 6 6 5 4 4 3 3 2 1 1
115 Volt s Distance In Feet To Center of Load
Amps 20 30 40 50 60 70 80 90 100 120 140 160
2
14 14 14 14 14 14 14 14 14 14 14 14
3
14 14 14 14 14 14 14 14 14 14 14 12
4
14 14 14 14 14 14 14 14 14 12 12 12
5
14 14 14 14 14 14 14 12 12 12 10 10
6
14 14 14 14 14 14 12 12 12 10 10 10
7
14 14 14 14 14 12 12 12 10 10 10 8
8
14 14 14 14 12 12 12 10 10 10 8 8
9
14 14 14 12 12 12 10 10 10 8 8 8
10
14 14 14 12 12 10 10 10 10 8 8 8
12
14 14 12 12 10 10 10 8 8 8 8 6
14
14 14 12 10 10 10 8 8 8 6 6 6
16
14 12 12 10 10 8 8 8 8 6 6 6
18
14 12 10 10 8 8 8 8 8 8 8 5
20
14 12 10 10 8 8 8 6 6 6 5 5
25
12 10 10 8 8 6 6 6 6 5 4 4
30 12
10 8 8 6 6 6 6 5 4 4 3
35 10
10 8 6 6 6 5 5 4 4 3 2
40 10 8 8 6 6 5 5 4 4 3 2 2
45 10 8 6 6 6 5 4 4 3 3 2 1
50 10 8 6 6 5 4 4 3 3 2 1 1
WIRE GAUGE CHART
ELECTRIC INSTALLATION & SAFETY
INFORMATION
• If the supply cord is damaged, it must be replaced by a special
cord or assembly available from the manufacturer or its
service agent.
• Lamps must be replaced by identical lamps only.
• Appliance tested according to the climate classes 5 and 7
temperature and relative humidity.
ELECTRICAL INSTRUCTIONS
A. Before your new unit is connected to a power supply, check
the incoming voltage with a voltmeter. If anything less than
100% of the rated voltage for operation is noted, correct
immediately.
B. All units are equipped with a service cord, and must be
powered at proper operating voltage at all times. Refer to
cabinet data plate for this voltage.
TRUE RECOMMENDS THAT A SOLE USE CIRCUIT BE
DEDICATED FOR THE UNIT.
WARNING:
Compressor warranties are void if compressor
burns out due to low voltage.
WARNING:
Power supply cord ground should not be removed!
WARNING:
Do not use electrical appliances inside the food
storage compartments of the appliances unless they are of the type
recommended by the manufacturer.
NOTE:
To reference wiring diagram, remove front louvered grill,