IMPORTANT WARRANTY INFORMATION
Condensers accumulate dirt and require cleaning every 30 days.
Dirty condensers result in compressor failure, product loss, and lost
sales, which are not covered by warranty.
If you keep the Condenser clean you will minimize your service
expense and lower your electrical costs. The Condenser requires
scheduled cleaning every thirty days or as needed.
Air is pulled through the Condenser continuously, along with dust,
lint, grease, etc.
A dirty Condenser can result in NON-WARRANTEED part &
Compressor Failures, Product Loss, and Lost Sales.
Proper cleaning involves removing dust from the Condenser. By
using a soft brush, or vacuuming the Condenser with a shop vac, or
using CO2, nitrogen, or pressurized air.
If you cannot remove the dirt adequately, please call your
refrigeration service company.
On most of the reach-in units the condenser is accessible in the
rear of the unit. You must remove the cabinet grill to expose the
Condenser.
The Condenser looks like a group of vertical fins. You need to
be able to see through the condenser for the unit to function
at maximum capacity. Do not place filter material in front of
condensing coil. This material blocks air-flow to the coil similar to
having a dirty coil.
THE CLEANING OF THE CONDENSER IS NOT
COVERED BY THE WARRANTY!
HOW TO CLEAN THE CONDENSER:
1. Disconnect the electrical
power to the unit.
2. Remove the louvered
grill.
3. Vacuum or brush the
dirt, lint, or debris from
the finned condenser
coil.
4. If you have a significant dirt build up you can blow out the
condenser with compressed air.
(CAUTION MUST BE USED TO AVOID EYE INJURY.
EYE PROTECTION IS RECOMMENDED.)
5. When finished be sure to replace the louvered grill. The grill
protects the condenser.
6. Reconnect the electrical power to the unit.
If you have any questions, please call TRUE Manufacturing at 636-
240-2400 or 800-325-6152 and ask for the Service Department.
Direct to Service Department 1(855)372-1368. Service
Department Availability Monday-Thursday 7:00 a.m. to 7:00 p.m.,
Friday 7:00 a.m. to 6:00 p.m. and Saturday 8:00 a.m. to 12:00 p.m.
CST.
Condensing Unit
Airflow
Airflow
Condenser