True Manufacturing Company GDM Series Installation Manual Download Page 21

www

.

truemfg

.

com

TEC_TM_020 REV. A

07/9/2020 

     Page 19 of 20

This warranty only applies to units shipped from True's manufacturing facilities after October 1, 2019 for USA Foodservice & Retail and after July 1, 2020 for Canada.

THREE-YEAR PARTS & LABOR WARRANTY

ADDITIONAL TWO-YEAR HFC COMPRESSOR WARRANTY AND ADDITIONAL FOUR-YEAR HYDROCARBON COMPRESSOR WARRANTY

404A/134A/HYDROCARBON COMPRESSOR WARRANTY

WARRANTY CLAIMS

WHAT IS NOT COVERED BY THIS WARRANTY

ENVIRONMENTAL ATTRIBUTES

 

 TRUE warrants to the original purchaser of every new TRUE refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, under normal 

and proper use and maintenance service as specified by TRUE and upon proper installation and start-up in accordance with the instruction packet supplied with each TRUE unit.  TRUE’s 
obligation under this warranty is limited to a period of three (3) years from the date of original installation or 39 months after shipment date from TRUE, whichever occurs first.
 

Any part covered under this warranty that is determined by TRUE to have been defective within three (3) years of original installation or thirty-nine (39) months after shipment date 

from manufacturer, whichever occurs first, is limited to the repair or replacement, including labor charges, of defective parts or assemblies.  The labor warranty shall include standard 
straight time labor charges only and reasonable travel time, as determined by TRUE.
 

Warranty does not cover standard wear parts which include door gaskets, incandescent bulbs or fluorescent bulbs.  Warranty also does not cover issues caused by improper 

installation or lack of basic preventative maintenance, which includes regular cleaning of condenser coils.

 

 In addition to the Three (3) year warranty stated above, TRUE warrants its hermetically and semi-hermetically sealed HFC compressor to be free from defects in both material 

and workmanship under normal and proper use and maintenance service for a period of two (2) additional years and for Hydrocarbon Units, an additional four (4) years from the date of 
original installation but not to exceed five (5) years and three (3) months for HFC compressors and not to exceed seven (7) years and three (3) months for HC compressors after shipment 
from the manufacturer.
 

Compressors determined by TRUE to have been defective within this extended time period will, at TRUE’s option, be either repaired or replaced with a compressor or compressor 

parts of similar design and capacity.
 

The two (2) year extended HFC or four (4) year HC extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the compressor and does 

not apply to any other parts or components, including, but not limited to: cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting equipment, fan 
assembly or any other electrical component, etcetera.

The two (2) year HFC compressor and four (4) year HC compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:

 

1.  This system contains R404A, R134A, or R290 refrigerant and polyol ester lubricant. The polyol ester lubricant has rapid moisture absorbing qualities.  If long exposure to the ambient  
 

conditions occur, the lubricant must be removed and replaced with new. For oil amounts and specifications please call TRUE technical service department (855-372-1368).  Failure to  

 

comply with recommended lubricant specification will void the compressor warranty.

 

2.  Drier replacement is very important and must be changed when a system is opened for servicing. An OEM exact replacement should be used.  The new drier must also be the same  
 

capacity as the drier being replaced.

 

3.  Micron level vacuums must be achieved to ensure low moisture levels in the system. 500 microns or lower must be obtained.

 

 All claims for labor or parts must be made directly through TRUE.  All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of 

installation, and all pertinent information supporting the existence of the alleged defect.
 

In case of warranty compressor, a picture of the compressor model tag must be returned to TRUE along with above listed information. For warranty claim information, visit www.

truemfg.com/Support/Warranty-Support. Any action for breach of these warranty provisions must be commenced within six (6) months of the defect giving rise to the breach.

 

TRUE’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below.  This warranty neither assumes nor authorizes any 

person to assume obligations other than those expressly covered by this warranty.
 

NO CONSEQUENTIAL DAMAGES.  TRUE IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, 

LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF REFRIGERATION FAILURE.
 

WARRANTY IS NOT TRANSFERABLE.  This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered.  ANY SUCH ASSIGNMENT OR TRANSFER 

SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
 

IMPROPER USAGE.  TRUE ASSUMES NO LIABILITY FOR PARTS OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER DAMAGES RESULTING FROM IMPROPER USAGE OR INSTALLATION OR 

FAILURE TO CLEAN AND/OR MAINTAIN PRODUCT AS SET FORTH IN THE WARRANTY PACKET PROVIDED WITH THE UNIT.
 

RELOCATION OF CABINET FOR REPAIR. True is not responsible for the cost to move a cabinet for any reason from its position of operation on the customer’s premises to make a warranty repair.

 

NON OEM PARTS.  Use of non OEM parts without manufacturer’s approval will void cabinet warranty.

 

ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD.  TRUE is not responsible for the repair or replacement of any 

parts that TRUE determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, flood, or act of God.
 

IMPROPER ELECTRICAL CONNECTIONS.  TRUE IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM INCORRECT SUPPLY VOLTAGE, 

THE USE OF EXTENSION CORDS, LOW VOLTAGE, OR UNSTABLE SUPPLY VOLTAGE.
 

NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE:  THERE ARE NO OTHER WARRANTIES, EXPRESSED, IMPLIED OR STATUTORY, EXCEPT THE THREE 

(3) YEAR PARTS & LABOR WARRANTY AND THE ADDITIONAL TWO (2) YEAR HFC COMPRESSOR AND THE ADDITIONAL FOUR (4) YEAR HC COMPRESSOR WARRANTY AS DESCRIBED ABOVE.  THESE 
WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  THERE ARE NO 
WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.
 

OUTSIDE U.S. AND CANADA: This warranty does not apply to, and TRUE is not responsible for, any warranty claims made on products sold or used outside the United States and Canada. 

This warranty only applies to units shipped from True’s manufacturing facilities after October 1, 2019 for US Foodservice & Retail and after July 1, 2020 for Canada.

Any and all environmental attributes, including environmental offset credit rights, with respect to TRUE® refrigeration units manufactured after September 1, 2015, shall remain the property 
of True Manufacturing Co., Inc. and are not transferred.

MS • 7/20

Warranty Information (USA & Canada Only)

Summary of Contents for GDM Series

Page 1: ...Precautions 1 Proper Disposal Connecting Electricity Adapter Plugs 2 INSTALLATION Ownership Uncrating 3 Wire Gauge Chart Electrical Installation 4 Locating and Leveling 5 Installation of Legs or Cast...

Page 2: ...TRUE glass door merchandisers health safety timer www truemfg com TEC_TM_020 REV A 07 9 2020 Page iii of 20...

Page 3: ...service this product All safety precautions must be followed CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used CAUTION R...

Page 4: ...SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord from this appliance is equipped with a grounding plug which minimizes the possibility of electric shock hazard Have the wall outlet and c...

Page 5: ...e incurred during shipment UNCRATING TOOLS REQUIRED Adjustable Wrench Phillips Screwdriver Level The following procedure is recommended for uncrating the unit A Remove the outer packaging cardboard an...

Page 6: ...0 10 10 10 8 8 8 12 14 14 12 12 10 10 10 8 8 8 8 6 14 14 14 12 10 10 10 8 8 8 6 6 6 16 14 12 12 10 10 8 8 8 8 6 6 6 18 14 12 10 10 8 8 8 8 8 8 8 5 20 14 12 10 10 8 8 8 6 6 6 5 5 25 12 10 10 8 8 6 6 6...

Page 7: ...may want to install an exhaust fan WARNING WARRANTY IS VOID IF VENTILATION IS INSUFFICIENT B Proper leveling of your TRUE cooler is critical to operating success for non mobile models Effective conde...

Page 8: ...o back and side to side diagonally B Install the desired number of shims making sure the slot of the shim is in contact with the threaded stem of the castor See image 2 C If more than one shim is used...

Page 9: ...eft and right sides parallel to the depth of the cooler Level cabinet STEP 3 Draw an outline on the base on the floor STEP 4 Raise and block the front side of the cabinet STEP 5 Apply a bead of NSF Ap...

Page 10: ...or able to wiggle out of the shelf standard SHELF CLIP INSTALLATION TIPS 1 Install all the shelf clips before installing the shelves 2 Start at the bottom in terms of shelf installation and work your...

Page 11: ...the UPS off press the power button for approximately 2 seconds you will hear a constant tone 1 second and release after two short beeps Quickly press the POWER button twice can turn off or turn on the...

Page 12: ...listed capacity of the UPS Turn the UPS off unplug at least one piece of equipment from battery outlets reset the circuit breaker and turn the unit on On Off On None Electrical Wiring Fault This indic...

Page 13: ...become necessary to replace temperature control be sure it is ordered from your TRUE dealer or recommended service agent D Good air flow in your TRUE unit is critical Be careful to load product so tha...

Page 14: ...d Servicing Delay OPERATION The Health Safety Timer cabinet s operation is determined by the electronic control The electronic control constantly monitors the cabinet temperature The control will acti...

Page 15: ...the non adjustable preprogrammed temperature c The control is designed to read and display a cabinet temperature not a product temperature This cabinet temperature may reflect the refrigeration cycle...

Page 16: ...AY LEGEND LED INDICATORS BUTTONS LED Off Locked LED ON Unlocked LED will blink to notify the key detection 2 CLEARING THE HEALTH SAFETY ALARM LOC HLA 1 Touch Enter twice to unlock the display This wil...

Page 17: ...value 00 5 Touch once to change the value to 01 6 Finally touch Enter 4 ADJUSTING THE SET POINT 1 Touch Enter twice to unlock the display 2 Touch Enter again to display the main menu InF will be the...

Page 18: ...nstall reattach the grill to the magnets on front of the cabinet and reinstall the screw on top of the grill Phillips Screwdriver Stiff Bristle Brush Adjustable Wrench Air Tank or CO2 Tank Vacuum Clea...

Page 19: ...ust remove the cabinet grill to expose the Condenser The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capacity Do...

Page 20: ...ffice 8 STEPS THAT CAN HELP PREVENT RUST ON STAINLESS STEEL 1 USING THE CORRECT CLEANING TOOLS Use non abrasive tools when cleaning your stainless steel products The stainless steel s passive layer wi...

Page 21: ...eplaced 3 Micron level vacuums must be achieved to ensure low moisture levels in the system 500 microns or lower must be obtained All claims for labor or parts must be made directly through TRUE All c...

Reviews: