background image

14

ONE YEAR LIMITED WARRANTY

SELECT BRANDS, INC. warrants, subject to the conditions stated below, that from the date of purchase, this product will be free from 

mechanical defects for a period of one (1) year.  SELECT BRANDS, INC., at its option, will repair or replace this product found to be 

defective during the warranty period.  Should this product become defective by reason of improper workmanship or material defect during 

the specified warranty period, Select Brands, Inc. will repair or replace the same effecting all necessary parts replacements for a period 

of one year from the date of purchase. 

Transportation charges on parts, or products in whole, submitted for repair or replacement, under this warranty, must be borne by the 

purchaser.

CONDITIONS: 

 This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable.  Keep 

the original sales receipt.  Proof of purchase is required to obtain warranty service or replacement.  Dealers, service centers, or retail 

stores do not have the right to alter, modify or in any way, change the terms and conditions of this warranty.

Warranty registration is not necessary to obtain warranty on Select Brands, Inc. products.  Save your proof of purchase receipt.  

ABOUT YOUR PRODUCT WARRANTY:  

Most warranty repairs are handled routinely, but sometimes requests for warranty service 

may not be appropriate.  For example, warranty service would NOT apply if the product damage occurred because of misuse, lack of 

routine maintenance, shipping, handling, warehousing or improper installation.  Similarly, the warranty is void if the manufacturing date 

or the serial number on the product has been removed or the equipment has been altered or modified.  During the warranty period, the 

authorized service dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal use 

and service.

NORMAL WEAR:  

This warranty does not cover normal wear of parts or damage resulting from any of the following: Negligent use or 

misuse of the product; Improper voltage or current; Use contrary to the operation instructions; Deviation from instructions regarding 

storage and transportation; Repair or alteration by anyone other than SELECT BRANDS, INC. or an authorized service center.  Further, 

the warranty does not cover Acts of God, such as fire, flood, hurricanes and tornadoes.

SELECT BRANDS, INC. shall not be liable for any incidental or consequential damages caused by the breach of any express or implied 

Summary of Contents for Crossover brewer CM-2000

Page 1: ...1 ...

Page 2: ...earest authorized service facility for examination repair or adjustment 7 The use of accessory attachments not recommended by the appliance manufacturer may result in fire electric shock or injury to persons 8 Do not use outdoors 9 Do not let cord hang over edge of table or counter or touch hot surfaces 10 Do not place on or near a hot gas or electric burner or in a heated oven 11 Extreme caution ...

Page 3: ...3 ...

Page 4: ...e over the countertop or tabletop where it can be pulled on by children or tripped over unintentionally POLARIZED PLUG This appliance has a polarized plug one blade is wider than the other To reduce the risk of electric shock this plug is intended to fit into a polarized outlet only one way If the plug does not fit fully into the outlet reverse the plug and try again If it still does not fit conta...

Page 5: ...rew Chamber during the brewing process UNPACKING 1 Carefully unpack the Brewer and all parts Remove any tape labels or packaging materials 2 Wash Removable Water Tank Water Tank Lid Drip Tray Drip Tray Cover K Cup Capsule Holder Brew Chamber Brew Chamber Adapter Shower Head Attachment Permanent Coffee Filter Basket Glass Carafe and Carafe Lid with warm soapy water Rinse well and dry thoroughly 3 W...

Page 6: ...and latch 7 Place the Glass Carafe on the Drip Tray and beneath the Brew Spout NOTE When using the Glass Carafe the Drip Tray must always be in place 8 Plug the Coffee Brewer into an electrical outlet Ideally the Coffee Brewer should be operated on its own circuit separate from other appliances 9 Turn the Coffee Brewer ON by pressing the Power Button All lights will be illuminated To prime push th...

Page 7: ...r on a dry level and heat resistant surface 2 Fill the Water Tank to the MAX level and make sure it is attached to the Brewer and properly seated on the Water Inlet DO NOT place any liquid other than water in the Water Tank Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Alignment Indicator ...

Page 8: ...be positioned closest to the Brew Chamber Handle when properly aligned 7 Insert the Shower Head Attachment into the center of the Brew Chamber Adapter by aligning the 3 tabs on the Shower Head Attachment with the 3 notches in the Brew Chamber Adapter Fig 3 8 Replace the Slide Out Brew Chamber into the Brewer making sure it is completely closed 9 Lower the Capsule Puncturing Locking Mechanism Fig 4...

Page 9: ...he Permanent Coffee Filter Basket from the Slide Out Brew Chamber 6 Insert the Brew Chamber Adapter into the Brew Chamber by aligning the 4 tabs on the Adapter with the 4 notches in the Brew Chamber Fig 2 NOTE There is an alignment indicator on the Brew Chamber Adapter that will closest to the Brew Chamber handle when properly aligned 7 Insert the Capsule Holder Attachment into the center of the B...

Page 10: ... and the brew size button selected will flash throughout the brewing cycle TIP To stop the brewing cycle at any time press the flashing button 14 When the brew cycle is complete the flashing button will stop and all five buttons will illuminate Five minutes after the brew cycle is complete the Brewer will automatically shut off 15 Do not leave used coffee capsules in the Brewer Wait for the Brewer...

Page 11: ... removed for further cleaning including the lower needle Should the lower needle become clogged because of coffee grinds a small household object or tool can be used to unclog the needle Use caution as the needle is sharp To remove the bottom portion of the Capsule Holder gently squeeze the rounded portion and pull until the lower section releases from the top section To replace use the two tabs o...

Page 12: ...and Shower Head Attachment into the Slide Out Brew Chamber Push the Brew Chamber properly in place and place the Glass Carafe on the Drip Tray Close the Capsule Puncturing Locking Mechanism and start a brew cycle without ground coffee or a coffee capsule by pressing the 10 Cups Button Power off the Brewer just after it begins to dispense and then allow it to sit for at least 30 minutes After allow...

Page 13: ...d the appliance keep it loosely coiled ALWAYS store the Brewer in an upright position as a small amount of water may remain in the boiler Excess power cord length can be tucked into the Cord Storage Compartment on the back of the Brewer On top of the Brewer is an Accessory Storage Compartment to store the Capsule Holder and the Shower Head Attachment Cord Storage Accessory Storage ...

Page 14: ...necessary to obtain warranty on Select Brands Inc products Save your proof of purchase receipt ABOUT YOUR PRODUCT WARRANTY Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty service would NOT apply if the product damage occurred because of misuse lack of routine maintenance shipping handling warehousing or improper in...

Page 15: ...ECT BRANDS INC Customer Service at 1 913 663 4500 A Customer Service representative will attempt to resolve warranty issues over the phone If telephone resolution is not possible the Customer Service representative will require your assistance in performing routine diagnostic procedures This warranty is effective for the time periods listed above and subject to the conditions provided for in this ...

Page 16: ......

Reviews: