32
3
Remove the four screws holding the PCA to the case front (see
Figure 14: PCA retaining screws)
.
4
Lift the PCA out of the case.
Figure 14: PCA
retaining screws
Refitting the PCA
1
EziWeigh5i – if necessary, replace the foam block which sits between the case front and the PCA.
This prevents unwanted movement inside the case.
2
Position the PCA in the case front..
Hint:
EziWeigh6i, EziWeigh7i, WOW2 and DAS WOW2 - It is easier to fit the LCD FPCs to the
PCA before fitting the PCA into the case.
3
Fit the four screws to fasten the PCA to the case front. If available, use a torque limited
screwdriver set to 0.5 Nm (4 lbf-in).
4
Connect the FPCs and looms (see
Figure 13: PCA connections
).
5
Reassemble the indicator.
Note:
Ensure that the case back is correctly installed. See page 24.