To access the
Density Offset
functions, press
¢
1
²
at the
Offset
menu.
DENSITY OFFSET
#.# pcf
1. Enable 2. Disable
3. Change Offset
The gauge displays the current density offset on the second line.
f
To enable the displayed density offset, press
¢
1
²
. The gauge
enables the offset, displays a brief confirmation message,
and returns to the
Ready
screen.
f
To disable the density offset, press
¢
2
²
. The gauge disables
the offset, displays a brief confirmation message, and
returns to the
Ready
screen.
NOTE
The density offset is also disabled when the gauge is
turned off.
f
To enter a new density offset, press
¢
3
²
. The gauge prompts
for the density offset as shown:
DENSITY OFFSET
#.# pcf
Select (+/-)
Input and <ENTER>
To change the offset, select the offset sign (positive or negative),
enter the density offset, and press
¢
ENTER/START
²
. The gauge
enables the new density offset and returns to the
Ready
screen.