7
–
8
As prompted, place the gauge on the measurement site and
press any key. The gauge takes a 240-second count, during
which it displays the progress of the count. Upon completion,
the gauge calculates and displays the moisture offset (
k
) as
shown:
K: ##.##
Save This Value
For Later Use?
f
To enable and use this moisture offset without storing it for
later use, press
¢
NO
²
. The gauge enables the offset and
returns to the
Ready
screen.
f
To enable the moisture offset and store it for later use, press
¢
YES
²
. The gauge displays:
Select Memory Cell:
1: #.## 2: #.##
3: #.## 4: #.##
Press # to Select
The gauge can store the value in one of four
memory cells
.
Storing a new value in a cell erases the old value. Use the
number keys to store the value. This will replace any stored
values that were previously associated with the memory cell.
The gauge stores the moisture offset, enables it for use, and
returns to the
Ready
screen.
Disable the Moisture Offset
To disable the moisture offset value, press
¢
6
²
at the
Moisture
Offset
menu. The gauge disables the moisture offset and returns
to the
Ready
screen.
NOTE
The moisture offset is also disabled when the gauge
is turned off.
Summary of Contents for RoadReader 3430
Page 14: ...1 6 Figure 1 Model 3440 Gauge and Accessories...
Page 19: ...Model 3440 2 3 Figure 2 Direct Transmission Geometry Figure 3 Backscatter Geometry...
Page 20: ...2 4 Figure 4 Backscatter Surface Density Effects Top Layer Effect Curves...
Page 22: ...2 6 Figure 5 Effect of Moisture on Depth of Measurement...
Page 164: ...F 2 STANDARD COUNT LOG Gauge Serial Number _____________ Date MS DS Date MS DS...