Appendix C–2
MEASUREMENT SPECIFICATIONS
Measurement capability
Pavement density in lb/ft
3
and
kg/m
3
Precision
0.2 lb/ft
3
(3.2 kg/m
3
) at 1-Sigma on
reference standard
Probe
Non-nuclear,
non-capacitance,
measuring field
Probing depth
Up to 4.45 cm (1.75 in.)
Measurement time
1
second
Measurement modes
Continuous, averaging, and
segregation