EN
8
Operating manual – dehumidifier TTR 56 E
6. Put the condensation tank back in.
7. Guide the other hose end to a suitable drain or sufficiently
dimensioned collection container. Please observe that the
hose must not be kinked.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch off the device.
•
Wait for approx. 2 minutes.
– Due to the follow-up time of the internal components,
the device only switches off completely after approx. 2
minutes.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Empty the condensation tank, if need be.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
•
Check the condensation tank for correct seating.
•
The device comes equipped with a tilt protection, it
switches off automatically when tilted. The operation
indicator light (44) must be illuminated in green. When the
lamp flashes, check whether device is in an upright
position on a level surface.
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but there is no formation of
condensate:
•
Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Ensure that the relative room humidity complies with the
technical data.
•
Check the air filter for dirt. If necessary, clean or replace
the air filter.
•
From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
•
Check the device for leaks.
The device gets very warm, is loud or loses power:
•
Check the air inlets and air filter for dirt. Remove external
dirt.
•
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
Notice
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Notice
For reasons of safety, the device switches off
automatically after a period of 24 hours.