background image

11

EN

Operating manual – dehumidifier TTR 56 E

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch off the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down completely.

Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the

device cleaned by a specialist company for cooling and air-
conditioning or by Trotec.

5. Put the air filter back in.

Cleaning the air filter

Notice

Ensure that the air filter is not worn or damaged. The
corners and edges of the air filter must not be
deformed or rounded. Before reinserting the air filter,
make sure that it is undamaged and dry!

The air filter has to be cleaned as soon as it is dirty. This is
brought to light e.g. by a reduced capacity (see chapter Errors
and faults).

1. Remove the air filter from the device.

2. Clean the filter using a slightly damp, soft, lint-free cloth. If

the filter is heavily contaminated, clean it with warm water
mixed with a neutral cleaning agent.

3. Allow the filter to dry completely. Do not insert a wet filter

into the device!

Summary of Contents for TTR 56 E

Page 1: ...TRT BA TTR56E TC 004 EN TTR 56 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...e Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in...

Page 3: ...to and following the technical data Intended use comprises dehumidifying and drying living rooms bedrooms bathrooms and basements laundries holiday homes camper vans boats maintaining the dryness of...

Page 4: ...withdrawn from the room air and cooled below dew point The water vapour contained in the room air precipitates in form of condensate The condensate drops into the condensation tank 6 The drier air thu...

Page 5: ...ensation tank prior to storage When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is protected from dust a...

Page 6: ...et Operation After being switched on the device operates fully automatically depending on the selected operating mode or until the float indicates that the condensation tank is full and the device swi...

Page 7: ...fficient time to cool down the device will remain in operation even for weeks Eco mode The device operates at low fan speed to save energy The heating switches off when the relative humidity in the am...

Page 8: ...mptied too frequently To do so proceed as follows A suitable hose diameter 12 mm is ready for use The device is switched off 1 Remove the condensation tank 2 Remove the protective cap at the condensat...

Page 9: ...ata Wait for 10 minutes before restarting the device If the device is not starting have the electrics checked by a specialist company or by Trotec The device is running but there is no formation of co...

Page 10: ...months at least annually Empty condensation tank and drain hose X Check the air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the in...

Page 11: ...xterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace air filter Check for damage Check the attachment sc...

Page 12: ...of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have t...

Page 13: ...by means of the POWER button 16 1 Take the condensation tank out of the device 2 Empty the condensation tank over a drain or sink 3 Rinse the tank with clear water Clean the tank regularly using a mi...

Page 14: ...h x height 200 x 445 x 525 mm Minimum distance to walls and other objects A top B rear C side D front 90 cm 40 cm 40 cm 50 cm Sound pressure level LpA 1 m complies with DIN 45635 01 KL3 45 dB A Wiring...

Page 15: ......

Page 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: