Operating manual – dehumidifier TTK 95 E

Operation with hose attached to the condensation
connection

For continuous operation or unattended dehumidification, please
connect a suitable condensation drain hose to the device.

ü

A suitable hose (diameter: 13 mm) is ready for use.

ü

The device is switched off.

1. Remove the sealing cap from the hose connection.
2. Remove the rubber plug.

3. Push one end of the hose onto the hose connection.

4. Guide the other hose end to a suitable drain or sufficiently

dimensioned collection container. Please observe that the
hose must not be kinked.

Remove the hose if you want to collect the condensate in the
condensation tank again. Allow the hose to dry prior to storage.
The hose can be connected in any operating mode for
continuous operation.

Summary of Contents for TTK 95 E

Page 1: ...TRT BA TTK95E TC 001 EN TTK 95 E EN OPERATING MANUAL DEHUMIDIFIER ...

Page 2: ...l helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed The current version of the operating manual can be found at TTK 95 E http hub trotec com id 39477 Legal notice This release replaces all previous versions No part of this publication may be reproduced without written permission from Trote...

Page 3: ...t operate it when wet Do not use the device with wet or damp hands Do not expose the device to directly squirting water Never insert any objects or limbs into the device Do not cover or transport the device during operation Do not sit on the device This appliance is not a toy Keep away from children and animals Do not leave the device unattended during operation Check accessories and connection pa...

Page 4: ...he Safety chapter Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air conditioning or by Trotec Residual risks Warning of electrical voltage Work on the electrical components must only be carried out by an authorised specialist company Warning of electrical voltage Before any work on the device remove the mains plug from the...

Page 5: ...below It is fitted with a float to measure the filling level The device has a control panel for operating and controlling the functions Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not installed correctly the condensation tank indicator light see chapter Operating elements on the control panel is illuminated The device switches off The cond...

Page 6: ...If so any warranty claims will be voided Storage Before storing the device proceed as follows Drain the remaining condensate from the device and the condensation drain hose see chapter Maintenance Empty and clean the condensation tank prior to storage When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is ...

Page 7: ...r other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residual current device which complies with the respective regulations Inserting the air filter Note Do not operate the device without an inserted air filter Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and...

Page 8: ...ive room humidity Indicates the desired relative room humidity during setting 14 Defrost indication Is displayed when automatic defrosting is in progress 15 Fan speed indication Indication of the fan speed low high laundry drying function 16 Swing function indication Is displayed when the swing function is activated 17 Ventilation button Setting the fan speed low high laundry drying function 18 Po...

Page 9: ...tween 1 and 24 and can be adjusted in increments of 1 h Note Do not leave the operating device unattended in a freely accessible room with an activated timer Automatic switch on 1 Switch off the device 2 Press the timer button 19 ð The number of hours flashes on the timer indication 21 3 Press the increase value 11 or decrease value button 23 to set the desired number of hours 4 Wait for approx 5 ...

Page 10: ...ce is switched off 1 Remove the sealing cap from the hose connection 2 Remove the rubber plug 3 Push one end of the hose onto the hose connection 4 Guide the other hose end to a suitable drain or sufficiently dimensioned collection container Please observe that the hose must not be kinked Remove the hose if you want to collect the condensate in the condensation tank again Allow the hose to dry pri...

Page 11: ...sation tank if need be Clean the device according to the Maintenance chapter Store the device according to the Storage chapter Errors and faults The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the power connection Check the power cable and mains plug...

Page 12: ... has tripped Disconnect the device from the mains and let it cool down for approx 10 minutes before reconnecting it The device might carry out an automatic defrost During automatic defrost the device does not dehumidify The device gets very warm is loud or loses power Check the air inlets and air filter for dirt Remove external dirt From the outside check the device for dirt see chapter Maintenanc...

Page 13: ...ent screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Empty condensation tank and drain hose Check the air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or...

Page 14: ... illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in Refrigerant circuit The entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by speci...

Page 15: ... detergent 4 Refit the condensation tank into the device Make sure not to damage the float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly Also make sure that the condensation tank is inserted correctly otherwise the device cannot be switched back on Activities required after maintenance If you want to continue using the device Leave th...

Page 16: ... PE 230 V 50 Hz Power input 0 6 kW Nominal current 2 6 A Refrigerant R134a Amount of refrigerant 215 g Condensation tank capacity 5 3 l Sound pressure level 1 m distance 47 dB A Dimensions length x width x height 240 x 368 x 560 mm Minimum distance to walls and other objects A top B rear C side D front 20 cm 20 cm 20 cm 20 cm Weight 16 kg Wiring diagram SCHEMATICWIRINGDIAGRAM N 1 2 5 1 52 1 2035 6...

Page 17: ...Operating manual dehumidifier TTK 95 E Spare parts drawing and list Info The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual 47 ...

Page 18: ... NHAF 29 PC BOARD 46 TOP COVER 13 BLOWER WHEEL 30 FIX METAL 47 HANDLE 14 FAN TANK 31 SENSOR FOR EVAPORATOR ASS Y 9 48 FIX TUBE 15 DISCHARGE GRILLE 32 POWER SUPPLY CORD COMPLETET ASS Y 49 Y TUBE 16 MICRO SWITCH 33 DECORATIVE PLARES 50 OVER LOAD PROTECTOR B90 135D 241A 17 FIX TUBE 34 DECORATIVE PLARES Disposal In the European Union electronic equipment must not be treated as domestic waste but must ...

Page 19: ......

Page 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: