background image

2

EN

dehumidifier TTK 71 E

Table of contents

Notes regarding the operating manual................................. 2

Safety ..................................................................................... 2

Information about the device................................................ 5

Transport and storage........................................................... 6

Assembly and installation..................................................... 7

Operation ............................................................................... 9

Errors and faults.................................................................. 11

Maintenance ........................................................................ 13

Technical annex................................................................... 17

Disposal ............................................................................... 20

Notes regarding the operating manual

Symbols

Danger

This symbol indicates dangers to the life and health of
persons due to extremely flammable gas.

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

TTK 71 E

https://hub.trotec.com/?id=42248

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms or
areas and do not install it there.

Do not use the device in aggressive atmosphere.

Only put up the device in an upright, stable position on firm
ground.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Never insert any objects or limbs into the device.

Do not cover or transport the device during operation.

Do not sit on the device.

This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Summary of Contents for ttk 71 e

Page 1: ...TRT BA TTK71E TC2013 05 007 EN TTK 71 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructio...

Page 3: ...ion the device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is no source of ignition e g open flames an active gas appliance or an ele...

Page 4: ...ders all claims for liability and guarantee null and void Personnel qualifications People who use this device must be aware of the dangers that occur when working with electric devices in damp areas h...

Page 5: ...Information about the device Description of the device The device uses the principle of condensation to automatically dehumidify rooms The fan sucks damp room air through the air inlet the air filter...

Page 6: ...After transporting the device observe the following Set up the device in an upright position after transport Leave the device to rest for 12 to 24 hours so the refrigerant can accumulate within the co...

Page 7: ...ervice Only position the device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is no source of ignition e g open flames an active gas ap...

Page 8: ...mage to the device Make sure that the air filter is installed before switching the device on Opening the ventilation flaps 1 Prior to switching the device on open the ventilation flaps at the air outl...

Page 9: ...s displayed when the timer is activated Indicates the number or hours set Is displayed automatic switch off enabled 17 TIMER button Starts programming for the timer function 18 MODE button Selection o...

Page 10: ...be adjusted in increments of 1 h Note Do not leave the operating device unattended in a freely accessible room with an activated timer Automatic switch off The device is switched on 1 Press the TIMER...

Page 11: ...The device does not start Check the power connection Check the power cable and mains plug for damage Check the on site fusing Check the filling level of the condensation tank and empty it if necessar...

Page 12: ...ed Disconnect the device from the mains and let it cool down for approx 10 minutes before reconnecting it The device might carry out an automatic defrost During automatic defrost the device does not d...

Page 13: ...or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and cl...

Page 14: ...entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning or by Trotec Safety signs a...

Page 15: ...air filter has to be cleaned as soon as it is dirty This is brought to light e g by a reduced capacity see chapter Errors and faults 1 Remove the air filter from the device 2 Clean the filter using a...

Page 16: ...ing or removing the condensation tank In doing so make sure that the float is positioned correctly Also make sure that the condensation tank is inserted correctly otherwise the device cannot be switch...

Page 17: ...ction side 1 2 MPa Pressure outlet side 2 5 MPa Max permissible pressure 2 5 MPa Mains supply 220 240 V 50 Hz Max power input 0 42 W Nominal current 1 8 A Refrigerant R290 Amount of refrigerant 55 g G...

Page 18: ...18 EN dehumidifier TTK 71 E Circuit diagram...

Page 19: ...Floater 1 20 Suction Tube 1 4 Back Cover Defence Net 1 21 Discharge Tube 1 5 Outlet Grids 1 22 Evaporator Inlet Tube 4 6 Back Cover 1 23 Condensor 1 7 Cover Right 1 24 Evaporator 1 8 Out Evaporator 1...

Page 20: ...dministration For further return options provided by us please refer to our website https de trotec com shop The separate collection of waste electrical and electronic equipment aims to enable the re...

Page 21: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: