Shutdown
1. Set the rotary switch (12) to position OFF (see chapter
Operating elements).
2. Do not touch the mains plug with wet or damp hands.
3. Remove the mains plug from the mains socket.
4. Empty the condensation tank and wipe it dry with a clean
cloth. Check for dripping condensation.
5. Clean the device, and especially the air filter, according to the
chapter Maintenance.
6. Store the device according to chapter Storage.
The accurate functionality of the device was tested during
production a number of times. However, if functionality faults do
occur, then check the device according to the following list.
The device does not start:
• Check the power connection.
• Check the mains plug for damages.
• Check that the condensation tank is positioned correctly.
Check the filling level of the condensation tank and empty it,
if necessary. The condensation tank indicator light must not
light up.
• Wait for 10 minutes before restarting the device. If the device
is not starting, have the electrics checked by a specialist
company for cooling and air-conditioning or by TROTEC®.
The device runs but forms no condensation:
• Check the float in the condensation tank for damages. If
necessary, clean the float and condensation tank. The float
must be able to move freely.
• Check the room temperature. Check the device's permissible
operating range complies with the technical data.
• Check that the selected desired humidity level. The humidity
in the room must be above the selected range. Reduce the
preselected humidity by turning the rotary switch (12), if
necessary.
• Check the air filter is not dirty. If necessary, clean or replace
the air filter.
• From the outside, check the condenser for dirt (see chapter
Maintenance). If your condenser is dirty, have it cleaned by a
specialist company for cooling and air-conditioning or by
TROTEC®.
The device is loud or vibrates; condensate is leaking:
• Check whether the device is standing upright and on an even
surface.
The device gets very warm, is loud or is losing performance:
• Check the position of the fins at the air outlet (2). The fins
ought to be open.
• Check the air inlets and air filter are not dirty. Remove
external dirt.
• From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and
air-conditioning or by TROTEC®.
Your device still does not operate correctly after these
checks?
Bring the device to a specialist company for cooling and
air-conditioning or to TROTEC
®
for repair.