Operating manual – dehumidifier TTK 110 HEPA
The compressor does not start:
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Ensure that the relative room humidity complies with the
technical data.
•
Check the preselected desired room humidity level. The
relative humidity in the room must be above the selected
range. If necessary, reduce the preselected desired room
humidity.
•
Check whether the
low ambient temperature
indication (31) flashes on the display. Possibly, the device
does not start because the ambient temperature is too low
(< 5 °C).
•
Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10 minutes before
reconnecting it.
•
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The fan does not start:
•
Check the operating mode. If the device is in
air
purification
mode and the HEPA filter is not inserted, the
fan will not start. Insert the HEPA filter in
air purification
mode (see Replacing the HEPA filter).
The device gets very warm, is loud or loses power:
•
Check the air inlets and air filters for dirt. Remove external
dirt.
•
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
Note:
Wait for at least 3 minutes after maintenance and repair work.
Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Error codes
The following error codes can be displayed:
Error code Cause
Remedy
EF
Motor fault
Disconnect the device
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.
E1
Fault at temperature
sensor
E2
Fault at humidity
sensor
E2
Fault at coil sensor