Operating manual – dehumidifier TTK 110 HEPA
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device will then carry out an
automatic defrost. Dehumidification is briefly interrupted during
defrosting.
The duration of the defrost process can vary. Do not switch off
the device during automatic defrost. Do not remove the mains
plug from the mains socket.
The
low ambient temperature
indication (31) flashes during
defrosting.
Drying laundry
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry.
For drying laundry the following values should be selected:
•
cupboard dry = 46 % relative humidity
•
iron dry = 58 % relative humidity
•
slightly dried = 65 % relative humidity
If necessary, use a measuring device to determine the humidity
level.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch off the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
If necessary, remove the condensation drain hose and any
residual fluid from it.
•
Empty the condensation tank, if need be.
•
If necessary, carry out self-cleaning (see Self-cleaning
function).
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Storage chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.
Accessories
Article number
HEPA filter
7.710.000.835
Carbon filter
7.710.000.836
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
•
Check the filling level of the condensation tank and empty
it if necessary. The
condensation tank full
indication (11)
must not be displayed.
•
Check the condensation tank for correct seating.
•
Check whether the
low ambient temperature
indication (31) flashes on the display. Possibly, the device
does not start because the ambient temperature is too low
(< 5 °C).
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but no condensate forms:
•
Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Ensure that the relative room humidity complies with the
technical data.
•
Check the preselected desired room humidity level. The
relative humidity in the room must be above the selected
range. If necessary, reduce the preselected desired room
humidity.
•
Check the air filter for dirt. If necessary, clean or replace
the air filter.
•
Check whether the
low ambient temperature
indication (31) flashes on the display. Possibly, the device
does not start because the ambient temperature is too low
(< 5 °C).
•
From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
•
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
•
Check the device for leaks.