Trotec TTK 100 E Operating Manual Download Page 19

EN

19

dehumidifier TTK 100 E

No. Spare Part

No. Spare Part

No. Spare Part

1

BASE PAN

16

CAPILLARY TUBE

31

SIDE PLATE

2

TURING WHEEL ASS'Y

17

FIX TURE

32

SIDE PLATE

3

COMPRESSOR ASS'Y (35D039-D1)

18

FAN MOTOR(YDK-08001304-WJ45) 33

PEAR PANEL

4

RUBBER

19

FAN CASING

34

HANDLE

5

SUCTION PIPE

20

BLOWER WHEEL

35

FRONT PANEL

6

DISCHARGE PIPE

21

SCREEN

36

CONTROL PLATE

7

PLATE

22

CAPACITOR(1.5uF/450V)(FOR FAN
MOTOR(18))

37

CONTROL PANEL

8

CAPACITOR (10uF/450V)(FOR
COMPRESSOR(3))

23

POWER SUPPLY CORD COMPLETE

38

INTAKE GRILLE

9

FIX METAL

24

FIX TURE

39

TANK LID

10

SENSOR (FOR EVA)

25

COVER

40

FIX TUBE

11

REED SWITCH

26

CONTROL BOARD

41

DRAIN BUCKET

12

DRAINAGE PAN

27

PC BOARD(FOR EVA )

42

2-WAY REVERSING VSLVE ASS'Y

13

EVAPORATOR ASS'Y

28

SENSOR

43

COVER

14

CONDENSER ASS'Y

29

FIX TURE

15

Y TUBE

30

FIX METAL

Disposal

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. You can also find out about other return options
that apply for many EU countries on the website 
https://hub.trotec.com/?id=45090. Otherwise, please contact an
official recycling centre for electronic and electrical equipment
authorised for your country.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

Have the refrigerant (propane) disposed of appropriately and
according to the national regulations by a company with the
relevant certification (European Waste Catalogue 160504).

Summary of Contents for TTK 100 E

Page 1: ...TRT BA TTK100E TC2019 35 010 EN TTK 100 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...r using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructi...

Page 3: ...device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is no source of ignition e g open flames an active gas appliance or an electric he...

Page 4: ...ad and understood the operating manual especially the Safety chapter Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air condi...

Page 5: ...r inlet the air filter the evaporator and to the condenser located behind it The air is cooled at the cold evaporator until it is below the dew point Water vapour contained in the room air precipitate...

Page 6: ...the device and the condensation drain hose see chapter Maintenance Do not use the power cable to drag the device Only wheel the device on a level and smooth surface After transporting the device proc...

Page 7: ...ground Do not create tripping hazards when laying the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension...

Page 8: ...ents of 10 13 Arrow button up 14 Speed button For setting a high or low fan speed Display 20 21 19 18 17 16 15 No Designation Meaning 15 Condensation tank full indication Is displayed when the condens...

Page 9: ...er of hours can be set in hourly increments 1 h to max 12 h Automatic switch on The device is now in standby mode 1 Repeatedly press the timer button 11 until the desired number of hours is displayed...

Page 10: ...n through the condensation tank opening 5 Put the condensation tank back in 6 Guide the other hose end to a suitable drain or sufficiently dimensioned collection container Please note that the hose mu...

Page 11: ...residual fluid from it Empty the condensation tank if need be Clean the device according to the Maintenance chapter Store the device according to the Transport and storage chapter Errors and faults Th...

Page 12: ...r maintenance and repair work Only then switch the device back on The device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to a...

Page 13: ...or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and c...

Page 14: ...abels on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp and lint free c...

Page 15: ...letely Do not insert a wet filter into the device 5 Put the air filter back in 6 Reinsert the flap into the device Emptying the condensation tank If the condensation tank is full or not inserted corre...

Page 16: ...essor damage and a malfunctioning device If so any warranty claims will be voided Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device acco...

Page 17: ...EN 17 dehumidifier TTK 100 E Wiring diagram...

Page 18: ...18 EN dehumidifier TTK 100 E Overview and list of spare parts Note The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual...

Page 19: ...rical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical...

Page 20: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: