EN
7
radial fan TFV 29 FS
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Cleaning the fan and device interior
Warning
Risk of injury caused by ejected compressed air upon
activation of the compressed air supply.
Hold the compressed-air hose away from your body.
Pointing the compressed-air hose at another person is
prohibited.
•
Check fan and protective grid for perfect condition before
and after each application.
•
Clean the fan after each operation.
•
Use compressed air to remove particles, lint, dust and dirt
from motor, fan wheel and protective grid. Do not in any
event use a high-pressure cleaner to clean the fan.
•
Other than that, the device does not require maintenance.
Technical annex
Technical data
Parameter
Value
Model
TFV 29 FS
Air flow rate
1,150 m³/h
Air discharge velocity
7 m/s
Stat. air pressure (freely
blowing)
max. 290 Pa
Max. transport medium
temperature
60 °C
Mains connection
1/N/PE ~ 230 V / 50 Hz
Power consumption, max.
0.17 kW
Nominal capacity
0.74 A
Connection cable
5 m
Protection type
IP44
Sound level (distance 3 m)
64 dB(A)
Dimensions (L x W x H)
520 x 450 x 255 (mm)
Weight
11 kg