6
EN
radial fan TFV 29 FS
Operation
Operating elements
1
6
5
9
No.
Designation
1
Operating hours counter
5
On/off switch
6
Service socket
9
Dual counter (operating hours counter and MID-certified
kilowatt hours counter) – (optional)
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Set the on/off switch (5) to
I
.
Stage 1 =
I
ð
The device is switched on.
Dual counter (optional)
The device is optionally available with a control panel fitted with
a dual counter (9). The dual counter registers both the operating
hours and energy consumption, and is MID-compliant.
Using the service socket
The device
TFV 29 FS
is equipped with a service socket, which
means that you can operate another device via the same
socket. The service socket is ready for operation as soon as the
devices are connected to the mains – they do not need to be
switched on.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Set the on/off switch (5) to
0
.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Storage chapter.
Available accessories
Available accessories
Article number
Dual counter, MID-compliant
7.140.000.903
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The fan is not running:
•
Check whether the device is switched on.
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
The fan operates only for a brief period, then switches off:
•
Check whether the protective grid at the air inlet is
obstructed in some way. If applicable, remove foreign
objects.
•
The motor bearing might be damaged. Please contact the
customer service.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.