background image

EN

3

radial fan TFV 29 FS

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The electrical connection must correspond to the
specifications in chapter Technical data.

Insert the mains plug into a properly secured mains
socket.

Observe the technical data when selecting extensions to
the power cable. Completely unroll the extension cable.
Avoid electrical overload.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

Observe the storage and operating conditions as given in
the Technical data chapter.

Make sure that the air inlet and outlet are not obstructed.

Make sure that there are no loose items or dirt located in
the immediate surroundings of air inlet and air outlet.

Make sure that the suction side is kept free of dirt and
loose objects.

Intended use

The device 

TFV 29 FS

 may be used for generating a broad near-

ground air current with a high air circulation for the accelerated
drying of flooring or to assist in drying walls, floors and
stairwells after water damage or else for construction drying. All
other applications are considered improper use.

Improper use

The radial fan is not suited for installation in fluids or on flooded
or boggy grounds. Any unauthorised changes, modifications or
alterations to the device are forbidden.

Personnel qualifications

People who use this device must:

have read and understood the instructions, especially the
Safety chapter.

Residual risks

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Caution

Risk of injury due to parts being whirled up by the
strong air current.
Before switching the device on, make sure that there
are no loose parts (clothing, hair etc.) located near the
air inlet or outlet!

Note

Do not use abrasive cleaners or solvents to clean the
device.

Behaviour in the event of an emergency

1. In an emergency, disconnect the device from the mains

feed-in: Switch the device off and disconnect it from the
mains.

2. Remove persons from the danger area.
3. Do not reconnect a defective device to the mains.

Summary of Contents for TFV 29 FS

Page 1: ...TRT BA TFV29FS TC2018 22 002 EN TFV 29 FS EN OPERATING MANUAL RADIAL FAN ...

Page 2: ...e the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or me...

Page 3: ...ulation for the accelerated drying of flooring or to assist in drying walls floors and stairwells after water damage or else for construction drying All other applications are considered improper use Improper use The radial fan is not suited for installation in fluids or on flooded or boggy grounds Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualific...

Page 4: ... speed in a broad near ground air current making this position ideal for accelerated surface drying In upright position the device can be used for well directed ventilation and drying of the ceiling When positioned on the edge with the air outlet pointing to the side the device can be used for ventilation and drying of confined spaces or extensive wall surfaces The device is further equipped with ...

Page 5: ...direct sunlight with a cover to protect it from invasive dust if necessary stackable up to 5 devices may be stacked on top of one another Info Do not take the devices into operation when stacked Stacking rules out an efficient usage of the devices Assembly and start up Scope of delivery 1 x Device 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove ...

Page 6: ...le pulling the power cable out of the mains socket Clean the device according to the Maintenance chapter Store the device according to the Storage chapter Available accessories Available accessories Article number Dual counter MID compliant 7 140 000 903 Errors and faults The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the ...

Page 7: ...essed air supply Hold the compressed air hose away from your body Pointing the compressed air hose at another person is prohibited Check fan and protective grid for perfect condition before and after each application Clean the fan after each operation Use compressed air to remove particles lint dust and dirt from motor fan wheel and protective grid Do not in any event use a high pressure cleaner t...

Page 8: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...