EN
13
electric heater TEH 200 / TEH 300 / TEH 400
Maintenance intervals
Maintenance and care interval
before every
start-up
as needed
at least every
2 weeks
at least every
4 weeks
at least every
6 months
at least
annually
Check air inlets and outlets for dirt
and foreign objects and clean if
necessary
X
Cleaning the exterior
X
X
Visual inspection of the inside of
the device for dirt
X
X
Checking of air inlet grid and air
filter for dirt and foreign objects
and cleaning or replacement if
necessary
X
X
Air filter replacement
X
Checking for damage
X
Checking the safety temperature
limiter
X
Check the attachment screws
X
X
Test run
X
Summary of Contents for TEH 200