background image

6

EN

cable drum PVD2 / PVD3 / PVD4

Operation

Connecting the cable drum

Unreel the cable to the desired length so as to operate
consumers with a total power of up to 1300 watts (PVD2)
or 1250 watts (PVD3 / PVD4).

Unreel the cable completely to operate consumers with a
total power of more than 1300 watts (PVD2) or
1250 watts (PVD3 / PVD4).

Do not create tripping hazards when laying the cable.

Insert the mains plug into a properly secured socket. On
the PVD3 and PVD4 models, the voltage indicator light (10)
lights up.

Connect consumers to the cable drum.

Thermal circuit breaker

The cable drum is equipped with a thermal circuit breaker
interrupting the current flow in case of overheating of the cable
drum. 
The thermal circuit breaker can be tripped if the cable drum has
not been unrolled completely or if the maximum rated power of
the consumer is too high.
Please proceed as follows if the thermal circuit breaker is
activated:

1. Pull the plug (3) from the socket.
2. Disconnect the consumer from the safety socket (9).
3. Unreel the cable completely.
4. Allow the cable to cool down completely.
5. Actuate the thermal circuit breaker (11).

ð

Now you can use the cable drum again.

Cleaning

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

Check the cable for damage.

Check whether the mains plug is inserted into a properly
secured socket.

Check whether the thermal circuit breaker has been
activated and, if necessary, deactivate it as described in
chapter Operation.

Disposal

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website https://de.trotec.com/shop/.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

Summary of Contents for PVD2

Page 1: ...TRT BA PVD2 PVD3 PVD4 TC2019 41 002 EN PVD2 PVD3 PVD4 EN OPERATING MANUAL CABLE DRUM ...

Page 2: ...tps hub trotec com id 43686 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This ...

Page 3: ...0 watts when unreeled and 1300 watts when rolled up For the PVD3 and PVD4 models the sum of the maximum permissible connected load must not exceed 3500 watts when unreeled and 1250 watts when rolled up Improper use Do not use the device in potentially explosive areas Do not place the device on wet or flooded ground Any unauthorised changes modifications or alterations to the device are forbidden P...

Page 4: ...ncy disconnect the device from the mains feed in Pull the mains plug 2 Do not reconnect a defective device to the mains Information about the device Device description The cable drum PVD2 is fitted with a black cable of 25 m length The cable drum PVD3 is fitted with a black cable of 40 m length the cable drum PVD4 is fitted with a yellow cable of 40 m length The cable drum comes equipped with dust...

Page 5: ...254 mm x 338 mm x 409 mm Weight packaging excluded approx 8 kg approx 10 kg Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport To make the device easier to transport it is fitted with a carry handle Before transporting the device observe the following Roll up the cable com...

Page 6: ...he mains socket Clean the device with a soft damp and lint free cloth Ensure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe the housing dry after cleaning Errors and faults The device has been checked for proper functioning several ...

Page 7: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: