background image

EN

5

cable drum PVD2 / PVD3 / PVD4

Front view PVD3 and PVD4

9

2

3

1

4

7

8

10

11

Rear view

5

6

No.

Designation

1

Carrying handle

2

Cable

3

Plug

4

Support point

5

Braking system

6

Slot for plug storage

7

Crank

8

Drum

9

Safety socket

10

Voltage indicator light

11

Thermal circuit breaker

Technical data

Parameter

PVD2

PVD3 / PVD4

Cable length

25 m

40 m

Cable cross-section

1.5 mm

2

2.5 mm

2

Max. power, rolled up 1300 W

1250 W

Max. power, unreeled 3600 W

3500 W

Nominal voltage

250 V

250 V

Nominal current

16 A

16 A

Number of sockets

3

4

Type of protection

IP 54

IP 54

Storage
(temperature)

-30 °C to 50 °C

-30 °C to 50 °C

Dimensions (length 
x width x height)

240 mm x 280 mm 
x 352 mm

254 mm x 338 mm 
x 409 mm

Weight (packaging
excluded)

approx. 8 kg

approx. 10 kg

Transport and storage

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Transport

To make the device easier to transport, it is fitted with a carry
handle.

Before

 transporting the device, observe the following:

Roll up the cable completely.

Put the plug into one of the two slots for plug storage.

Make sure that the braking system of the drum prevents
an inadvertent unreeling of the cable.

Storage

When the device is not being used, observe the following
storage conditions:

dry and protected from frost and heat

protected from dust and direct sunlight

with a cover to protect it from invasive dust, if necessary

The storage temperature is the same as the range given in
the Technical data chapter.

Summary of Contents for PVD2

Page 1: ...TRT BA PVD2 PVD3 PVD4 TC2019 41 002 EN PVD2 PVD3 PVD4 EN OPERATING MANUAL CABLE DRUM ...

Page 2: ...tps hub trotec com id 43686 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This ...

Page 3: ...0 watts when unreeled and 1300 watts when rolled up For the PVD3 and PVD4 models the sum of the maximum permissible connected load must not exceed 3500 watts when unreeled and 1250 watts when rolled up Improper use Do not use the device in potentially explosive areas Do not place the device on wet or flooded ground Any unauthorised changes modifications or alterations to the device are forbidden P...

Page 4: ...ncy disconnect the device from the mains feed in Pull the mains plug 2 Do not reconnect a defective device to the mains Information about the device Device description The cable drum PVD2 is fitted with a black cable of 25 m length The cable drum PVD3 is fitted with a black cable of 40 m length the cable drum PVD4 is fitted with a yellow cable of 40 m length The cable drum comes equipped with dust...

Page 5: ...254 mm x 338 mm x 409 mm Weight packaging excluded approx 8 kg approx 10 kg Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport To make the device easier to transport it is fitted with a carry handle Before transporting the device observe the following Roll up the cable com...

Page 6: ...he mains socket Clean the device with a soft damp and lint free cloth Ensure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe the housing dry after cleaning Errors and faults The device has been checked for proper functioning several ...

Page 7: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...