background image

EN

2

Operating manual – cordless multi-function tool PMTS 10-20V

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

The term 

power tool

 used in the safety warnings refers to both

mains-operated and battery-powered electric tools (with/
without power cable).

General Power Tool Safety Warnings – Work area
safety 

Keep work area clean and well lit.

 Cluttered or dark

areas invite accidents.

Do not operate power tools in explosive atmospheres,
such as in the presence of flammable liquids, gases or
dust.

 Power tools create sparks which may ignite the dust

or fumes.

Keep children and bystanders away while operating a
power tool.

 Distractions can cause you to lose control.

General Power Tool Safety Warnings – Electrical
safety

Power tool or power adapter plugs must match the
outlet. Never modify the plug in any way. Do not use
any adapter plugs with earthed (grounded) power
tools.

 Unmodified plugs and matching outlets will reduce

risk of electric shock.

Avoid body contact with earthed or grounded surfaces,
such as pipes, radiators, ranges and refrigerators.

There is an increased risk of electric shock if your body is
earthed or grounded.

Do not expose power tools to rain or wet conditions.

Water entering a power tool will increase the risk of
electric shock.

Do not abuse the cord. Never use the cord for carrying,
pulling or unplugging the power tool. Keep cord away
from heat, oil, sharp edges or moving parts.

 Damaged

or entangled cords increase the risk of electric shock.

When operating a power tool outdoors, use an
extension cord suitable for outdoor use.

 Use of a cord

suitable for outdoor use reduces the risk of electric shock.

If operating a power tool in a damp location is
unavoidable, use a residual current device (RCD)
protected supply.

 Use of an RCD reduces the risk of

electric shock.

General Power Tool Safety Warnings – Personal
safety

Stay alert, watch what you are doing and use common
sense when operating a power tool. Do not use a
power tool while you are tired or under the influence of
drugs, alcohol or medication.

 A moment of inattention

while operating power tools may result in serious personal
injury.

Use personal protective equipment. Always
wear eye protection.

 Protective equipment such

as protective mask, non-skid safety shoes, hard
hat, hearing protection or tight-fitting protective
clothing used for appropriate conditions will
reduce personal injuries.

Prevent unintentional starting. Ensure the switch is in
the off-position before connecting to power source
and/or battery pack, picking up or carrying the tool.

Carrying power tools with your finger on the switch or
energising power tools that have the switch on invites
accidents.

 

Remove any adjusting key or wrench before turning

the power tool on.

 A wrench or a key left attached to a

rotating part of the power tool may result in personal
injury.

Do not overreach. Keep proper footing and balance at
all times.

 This enables better control of the power tool in

unexpected situations.

Dress properly. Do not wear loose clothing or
jewellery. Keep your hair, clothing and gloves away
from moving parts.

 Loose clothes, jewellery or long hair

can be caught in moving parts.

 

If devices are provided for the connection of dust

extraction and collection facilities, ensure these are
connected and properly used.

 The use of a dust

extraction system may reduce dust-related hazards.

Summary of Contents for PMTS 10-20V

Page 1: ...TRT BA PMTS10 20V TC 001 EN PMTS 10 20V EN OPERATING MANUAL CORDLESS MULTI FUNCTION TOOL...

Page 2: ...This signal word indicates a hazard with a low risk level which if not avoided can result in minor or moderate injury Notice This signal word indicates important information e g material damage but do...

Page 3: ...g a power tool will increase the risk of electric shock Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving pa...

Page 4: ...jects like paper clips coins keys nails screws or other small metal objects that can make a connection from one terminal to another Shorting the battery terminals together may cause burns or a fire Re...

Page 5: ...s either Water entering a power tool will increase the risk of electric shock Do not treat the surface to be processed with liquids containing solvents Toxic fumes may be produced during scraping owin...

Page 6: ...ing the insertion tool Do not touch the insertion tool bare handed Wear protective gloves Warning of sharp object Parts of the saw blade are sharp Risk of injuries if handled without due care Wear pro...

Page 7: ...stem included in the scope of delivery to a vacuum cleaner The integrated LED work lamp offers an improved illumination of the workpiece or working surface The battery comes with its own battery level...

Page 8: ...l PMTS 10 20V Nominal voltage 20 V Idle speed 5 000 19 000 rpm Oscillation angle 3 2 Weight 1 25 kg Battery PMTS 10 20V DC Type Li ion Nominal voltage 20 V Capacity 2 Ah Quick charger PMTS 10 20V AC I...

Page 9: ...w the device to cool down Remove the battery from the device Remove the tool from the tool holder If attached disconnect the dust extraction system from the device The supplied Li ion batteries are su...

Page 10: ...temperatures below 10 C or above 40 C The battery is partially charged upon delivery to avoid damage to the battery caused by a deep discharge Prior to initial start up and when the battery is low on...

Page 11: ...ation 8a 8a 19 Mounting the handle Info Use the supplied anti vibration handle for safe and precise guiding The anti vibration handle 14 should be mounted before start up To do so please proceed as fo...

Page 12: ...end tools may however be used Tool change with a closed end If you use insertion tools with a ring shaped end the clamping screw needs to be removed for tool change Warning of electrical voltage Befor...

Page 13: ...ck whether the tool is properly locked in place Oscillation rate selection The required oscillation rate depends on the material and the operating conditions and can be determined by way of field test...

Page 14: ...blunt or otherwise damaged cutting blades could break When cutting wall tiles bear in mind that the insertion tools are subjected to a high level of wear during longer operation Scraping Choose a hig...

Page 15: ...r Applying sandpaper The delta sanding plate is provided with a hook and loop fastening system so as to allow a quick and easy attachment of Velcro backed sanding sheets Please proceed as follows to a...

Page 16: ...Accessories Article number Accessory kit 1 Universal comprising 1 x scraping knife HCS SC 80 30 for removing tile adhesive silicone mortar and paint residues 1 x segment saw blade HSS SM 85 20 for woo...

Page 17: ...e The battery must lock in place in the device Check the battery terminals for dirt Remove any dirt Info Wait for at least 10 minutes before switching the device back on The tool is loose Make sure th...

Page 18: ...d chips from the tool holder Regularly clean the delta sanding plate by tapping it out for a better adhesion of the sandpaper Use a wire brush to clean the RIFF tools available accessories Keep the co...

Page 19: ......

Page 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: