EN
23
air cooler PAE 45
8. Insert the evaporation filters (
8
) on both sides of the
device.
9. Insert the air inlets with air filters (
9
) on both sides of the
device.
9
8
Activities required after maintenance
If you want to continue using the device:
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Transport and storage
chapter.
Technical annex
Technical data
Parameter
Value
Model
PAE 45
Evaporation capacity
1200 ml/h
Air flow rate
1700 m³/h
Mains connection
220-240 V / 50 Hz
Nominal current consumption 0.2 A
Power consumption
90 W
Sound pressure level (1 m
distance)
60 dB(A)
Water tank capacity
10 l
Weight
7.5 kg
Dimensions (length x width x
height)
290 x 368 x 940 mm
Minimum distance to walls and
other objects:
top (A):
rear (B):
sides (C):
front (D):
100 cm
100 cm
100 cm
100 cm
Remote control batteries
3 V CR2032