radiant heater IR 2010 / IR 3010

7. Make sure that the device is attached securely.

8. Tilt the device to the desired angle. The device can be

tilted upwards and downwards by 60°.
Use the Allen wrench to fix the inclination angle.

60°

Start-up

Note

Please use a safety fuse (overcurrent protection device)
or a type C circuit breaker.

Note

Current peaks in the millisecond range may occur
temporarily during switch-on of the device. With an
output of up to 3,000 watts, this may cause
category 16A-B circuit breakers to trigger and to
become defective in the long run.
If necessary, have the fuses replaced by a specialist
electrical company.

Info

Odours might arise upon initial start-up or after a
longer period of non-use.

Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.

Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.

Make sure that extension cables are completely unrolled.

Make sure that there are no curtains or similar objects in
the immediate vicinity.

Connecting the power cable

Insert the mains plug into a properly secured mains
socket.

Make sure that the power cable is guided along the back
of the device. Never guide the power cable along the front
of the device!

Summary of Contents for IR 2010

Page 1: ...TRT BA IR2010 IR3010 TC2017 38 001 EN IR 2010 IR 3010 EN OPERATING MANUAL RADIANT HEATER ...

Page 2: ...llowing link IR 2010 https hub trotec com id 41229 IR 3010 https hub trotec com id 43687 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury ...

Page 3: ...o avoid a hazard Defective power cables pose a serious health risk During the installation of the device observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter Do not use the device in immediate proximity to curtains Do not transport the device during operation Allow the device to cool down before transport...

Page 4: ...ot place the device on combustible ground Do not place the device on high pile carpets Warning Risk of injury due to infrared radiation Do not stay in the device s immediate vicinity for too long Do not look directly into the device for too long Observe the minimum distances Warning In order to avoid overheating and fire hazards the heater must not be covered Warning Coarse dirt particles on the h...

Page 5: ... plug while pulling the power cable out of the mains socket Do not use the power cable to drag the device Allow the device to cool down sufficiently Storage Before storing the device proceed as follows Hold onto the mains plug while pulling the power cable out of the mains socket Allow the device to cool down sufficiently When the device is not being used observe the following storage conditions d...

Page 6: ... if the required minimum distances are not observed The device must be positioned at a distance of at least 180 cm from the floor and at least 50 cm from walls and other objects such as curtains or sockets Installation When installing the device observe the minimum distances from walls and other objects as described in the Technical data chapter Minimum distance of 180 cm from the floor Minimum di...

Page 7: ...crews and wing nuts 7 Make sure that the device is attached securely 8 Tilt the device to the desired angle The device can be tilted upwards and downwards by 90 Use the Allen wrench to fix the inclination angle 90 IR 3010 1 Mark the drill holes on the wall 2 Drill the holes into the wall at the marked positions 3 Insert suitable wall plugs into the drill holes 4 Screw the mounting brackets to the ...

Page 8: ...replaced by a specialist electrical company Info Odours might arise upon initial start up or after a longer period of non use Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Do not create tripping hazards when laying the power cable or other electric cables especially when positioning the device in the m...

Page 9: ...tch it on 1 Set the on off switch 1 to I ð The device is switched on Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Switch the device off by setting the on off switch 1 to the 0 position Allow the device to cool down completely Hold onto the mains plug while pulling the power cable out of the mains socket Clean the device according to the Maintenance chap...

Page 10: ...on are a normal process No measures are required Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorized specialist electrical company or to Trotec for repair Maintenance Activities required before starting...

Page 11: ... the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by ...

Page 12: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: